Kohler Command PRO EFI Series Service Manual page 63

Table of Contents

Advertisement

ORIGINAL DESIGN Electronic Governor Troubleshooting Flow Chart Continued
12 Volt
Locate Speed Control input wire. This connection is a single wire red with yellow tracer.
Power
See illustration on page 59.
Test
Unplug and connect a jumper wire to red wire with a yellow tracer on engine wire harness.
Start engine in normal manner as described in Owner's Manual. (Engine will initially operate at speed it was
last run or shut down, then will go to idle).
Attach open end of jumper wire to positive (+) battery terminal.
Engine speed increases
(if it was at low speed).
Fail
Engine speed does not change.
Review GCU blink codes with chart on page 60 to identify if a system condition is present.
Proceed to Ground/Power and OHMs test for GCU. Refer to page 58.
Remove GCU and unplug wiring harness. See illustration on page 56.
GCU Circuit Test.
Inspect wiring harness for broken wire or bad connections. (Repair/Replace as required).
Test supply ground circuit to GCU using a continuity OHM/tester. Refer to page 58.
Continued on next page
62 690 05 Rev. E
Operation Input Voltage:
0-1 Volts at Idle/9+ Volts at High Speed.
Kohler electronic governor system tests OK. Test
Pass
control system of equipment. Refer to Equipment
Manufacturer's diagnostic procedures for control
system.
KohlerEngines.com
Governor System
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Command pro efi ecv940Command pro efi ecv980

Table of Contents