2.2

Equipment preparation

Softener
On request, an automatic resin softener is supplied.
For further information, refer to chapter "Softeners".
Filter holder
In the housing of the filter holder (1) place the spring
to stop the filter (2). Take the two cups (3) or one-cup (4)
filter and press it firmly into the filter holder.
Spouts
Complete the filter holder by installing the 2 cups (6)
or one-cup (5) spout.
3
2
1
6
5
i
Install the spout with relative filter: one-cup spout
on one-cup filter holder or with one-cup filter, etc...
14
Motor pump (only for version 1GR)
For the machines with an external motor, it is
necessary to prepare the pump and the motor.
Assemble the 3/8 gas connection with the inlet filter
(2) of the pump (arrow ) and the plain 3/8 outlet gas
connection (1) of the pump (arrow ).
Use the special washers (3) provided for sealing
purposes.
To correctly couple the pump and motor, use the
appropriate joint (4) and the spacer ring (5), lock
everything with the two clamps (6).
The pump and motor joint has to be installed also on
the machines with an internal motor pump.
!
4
6
5
4
Install the connection with the inlet filter
the pump (arrow
).
1
2
3
3
6
of
(2)