Ats10 Set Disconnect Delay After Indicating The Absence Of Data Carrier; Ats18 Extended Error Report; Att Select Tone Dialling - Siemens TC37 Module At Command Reference

At command set cellular engines
Table of Contents

Advertisement

AT Command Set

2.28 ATS10 Set disconnect delay after indicating the absence of data carrier

Read command
Response
ATS10?
<n> OK
This parameter setting determines the amount of time, that the TA remains
Write command
connected in absence of a data carrier. If the data carrier is detected before
ATS10=<n>
disconnect, the TA remains connected.
Response
OK
Parameter
<n>
Reference
Note
V.25ter

2.29 ATS18 Extended error report

Test command
Response
ATS18?
<n> OK
Execute command
TA returns an extended report of the reason for the last call release and location.
ATS18=<n>
<n>
Response
+Cause: <location ID>: <reason > OK
Parameter
<location ID>
<reason>
Reference
Note
Siemens
This command works for data calls only. For voice calls please use AT+CEER.

2.30 ATT Select tone dialling

Execute command
Response
ATT
OK
Reference
Note
V.25ter
No effect for GSM
TC3X_ATC_01_V04.00
001-002-254
number of tenths of seconds of delay
0 – 255, odd numbers set extended error report and even
numbers disable this feature.
Location ID as number code (see subclause 7.1.5).
Reason for last call release as number code (see subclause
7.1.5).