AT Command Set

2.11 ATE Enable command echo

Write command
This setting determines whether or not the TA echoes characters received from
TE during command state.
ATE[<value>]
Response
OK
Parameter
<value> 0 Echo mode off
Reference
Note
V.25ter
In case of using the command without parameter, <value> is set to 0.

2.12 ATH Disconnect existing connection

Execute command
Disconnects any call in progress, such as voice calls, fax or CSD data calls.
ATH[n]
Response
OK
Note:
OK is issued after circuit 109 (DCD) is turned off (RS-232 level), if it was
previously on.
Parameter
<n>
Reference
Note
V.25ter
Using ATH in Multiplex mode (AT+CMUX)
· ATH terminates every data call, even if it is issued via logical channels 2 or 3.
· This behaviour is in accordance with ITU-T V.25 ter; (07/97, see „6.3.6 Hook
control": "ATH is terminating any call in progress.")
TC3X_ATC_01_V04.00
1 Echo mode on
0 terminate call
Page 24 of 204