AT Command Set

2.26 ATS7 Set number of seconds to wait for connection completion

Read command
Response
ATS7?
<n> OK
Write command
Specifies the number of seconds the TA will wait for the completion of the call
ATS7=<n>
setup when answering or originating a data call. Also referred to as "no answer
timeout". To put it plainly, this is the time to wait for the carrier signal. If no carrier
signal is received within the specified time, the TA hangs up.
Response
OK
Parameter
<n>0 <n>
Reference
Note
V.25ter
· Values greater than 60 cause no error, but <n> will be restored to the
· If called party has specified a high value for ATS0=<n>, call setup may fail.
· The correlation between ATS7 and ATS0 is important.
· ATS7 is only applicable to data calls.

2.27 ATS8 Set number of seconds to wait for comma dial modifier

Read command
Response
ATS8?
<n> OK
Write command
No effect for GSM
ATS8=<n>
Response
OK
Reference
Note
V.25ter
TC3X_ATC_01_V04.00
000 – 060 no. of seconds to wait for connection completion.
maximum value of 60.
Example: Call setup may fail if ATS7=30 and ATS0=20.
Page 30 of 204
29.05.2002