4.5

Installation

Figure 4-6
Crane lifting lugs
Power Modules are fitted with crane lifting lugs as standard when shipped. The units can be
hoisted using these lugs and transported from the pallet to the installation location.
Note
Transport in the horizontal position
Transport in the horizontal position is permissible.
It is not permissible to screw the crane lifting lug into the thread at the lower side of the
Power Module.
NOTICE
Damage to the device due to improper transport
Improper transport can cause mechanical loads on the housing or busbars which can result
in damage to the device.
• Use a lifting harness with vertical ropes or chains during transport.
• Do not use the busbars as handles or for fastening a lifting harness.
• Only tighten the crane lifting lugs by hand. Remove the crane lifting lugs after the
Water-cooled chassis power units for common cooling circuits
Manual, 08/2017, 6SL3097-4AM10-0BP0
Crane lifting lugs / screw coupling points for mechanical support
installation, but keep them for later use.