7 - DETAILED MENU STRUCTURE
Pump Configuration Menu – PUMPCONF
No. Name
Status
1
hpumpseq
0 to 1
2
cpumpseq
0 to 1
3
4
5
pump_per
no/yes
6
pump_sby
no/yes
7
pump_loc
no/yes
8
stopheat
no/yes
9
stopcool
no/yes
*Displayed in English by default.
Reset Configuration Menu – RESETCFG
No. Name
Status
1
cr_sel
0 to 4
2
hr_sel
0 to 4
3
4
5
6
7
8
oat_crno
-10 to 51.7
14 to 125
9
oat_crfu
-10 to 51.7
14 to 125
10
dt_cr_no
0 to 13.9
0 to 25
11
dt_cr_fu
0 to 13.9
0 to 25
12
v_cr_no
0 to 20
13
v_cr_fu
0 to 20
14
spacr_no
-10 to 51.7
14 to 125
15
spacr_fu
-10 to 51.7
14 to 125
16
cr_deg
-16.7 to 16.7
-30 to 30
17
18
19
oat_hrno
-10 to 51.7
14 to 125
20
oat_hrfu
-10 to 51.7
14 to 125
21
dt_hr_no
0 to 13.9
0 to 25
22
dt_hr_fu
0 to 13.9
0 to 25
23
v_hr_no
0 to 20
24
v_hr_fu
0 to 20
25
spahr_no
-10 to 51.7
14 to 125
26
spahr_fu
-10 to 51.7
14 to 125
27
hr_deg
-16.7 to 16.7
-30 to 30
*Displayed in English by default.
Default Unit Displayed text *
0
-
Condenser Pumps
Sequence
0
-
Cooler Pumps Sequence
0 = No Pump
1 = One Pump Only
no
-
Pump Sticking Protection
no
-
Stop Pump During Standby Pump stopped during standby
yes
-
Flow Checked If Pump Off
no
-
Cooler Pump Off In Heat
no
-
Cond Pump Off In Cool
Default Unit Displayed text *
0
-
Cooling Reset Select
0
-
Heating Reset Select
0=None, 1=OAT
2=Delta T, 4=Space Temp
3=4-20mA control
Cooling
-10
°C
OAT No Reset Value
14
°F
-10
°C
OAT Full Reset Value
14
°F
0
^C
Delta T No Reset Value
0
^F
0
^C
Delta T Full Reset Value
0
^F
0
mA
Current No Reset Value
0
mA
Current Full Reset Value
-10
°C
Space T No Reset Value
14
°F
-10
°C
Space T Full Reset Value
14
°F
0
^C
Cooling Reset Deg. Value
0
^F
Heating
-10
°C
OAT No Reset Value
14
°F
-10
°C
OAT Full Reset Value
14
°F
0
^C
Delta T No Reset Value
0
^F
0
^C
Delta T Full Reset Value
0
^F
0
mA
Current No Reset Value
0
mA
Current Full Reset Value
-10
°C
Space T No Reset Value
14
°F
-10
°C
Space T Full Reset Value
14
°F
0
^C
Heating Reset Deg. Value
0
^F
Description
Condenser pumps sequence
Cooler pumps sequence
0 = no pump
1 = one pump only
Pump anti-sticking protection
Water flow is checked when the pump is off
Cooler pump is off when the unit is in Heating
Condenser pump is off when the unit is in Cooling
Description
Reset source in Cooling
Reset source in Heating
0 = None
1 = OAT
2 = Delta T
4 = Space temperature
3 = 4-20 mA signal
Cooling
OAT, no reset value
(applies to units with a Dry Cooler at the condenser)
OAT, max. reset value
(applies to units with a Dry Cooler at the condenser)
Delta T, no reset value
Delta T, max. reset value
Current, no reset value
Current, max. reset value
Space temperature, no reset value
Space temperature, max. reset value
Cooling reset value
Heating
OAT, no reset value
(applies to units with a DryCooler at the condenser)
OAT, max. reset value
(applies to units with a DryCooler at the condenser)
Delta T, no reset value
Delta T, max. reset value
Current, no reset value
Current, max. reset value
Space temperature, no reset value
Space temperature, max. reset value
Heating reset value