Installing, exchanging and connecting modules
6
Installing an Ethernet switch (modular) FN2012

6.15.6 Pin assignments

6.15.6.1 'POWER' connector strip
138 | 222
Building Technologies
Fire Safety
The 'POWER' connector is only used if power cannot be supplied via the MoNet
bus or PoE. Generally, this is only the case if the Ethernet switch (modular) is
installed remotely in another device. Power must be supplied via a DC 24 V power
supply unit with a regulated and power-limited output that has been listed for
signaling fire.
Designation
Description
A+
Supply input 1 (+DC 24 V)
A-
Common supply input 1 (DC 0 V)
B-
Not connected
B+
Not connected
Admissible cable cross-section: 0.2...2.5 mm²
B+
B-
A-
A+
Connector FN2012
POWER
Terminal Plug
+24V
GND
Supply input
A6V10210390_j_en_--
2015-12-15