Vulcan-Hart C24EA Series Service Manual page 48

Electric convection steamers
Hide thumbs Also See for C24EA Series:
Table of Contents

Advertisement

C24EA SERIES ELECTRIC CONVECTION STEAMERS - CONTROL BOARD
STATUS
LED
ON
OFF
Vacuum relief solenoid (5SOL)
12
X
energized.
13
X
Same as Delime Switch On
14
X
Delime Relay (K4) de-energized.
15
X
Delime Relay (K2) de-energized.
17
X
Same as Delime Switch On
All other LED's are off.
Delime Cycle Ends
LED's 1, 9, 12 and 13 remain lit.
All other LED's are off.
Steamer is off.
F35453 Rev. A (0119)
COMPONENT
Page 48 of 75
DESCRIPTION
Pressure switch (2PAS) contacts close. Solenoid
valve opens to provide air vent and allow steam
generator to drain.
K4-5/3 contacts open. Power light off.
K4-6/4 contacts open. Power removed from delime
2 (TDR).
K2-6/4 contacts open. Delime light off.
Power removed from delime 1 (TDR) input trigger,
delime 1 (TDR) remains powered thru K7-5/3 N.O.
contacts to hold delime relay (K7) energized for a
delay on dropout (120VAC output from load
terminal remains on). Allows heat exchanger to
drain (along with steam generator during the 3
minute drain cycle time.
K2-5/1 contacts open. Power to cooking
compartment controls no longer locked out.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C24ea6C24ea10

Table of Contents