C24EA SERIES ELECTRIC CONVECTION STEAMERS - THERMOSTAT AND HIGH LIMITS
Fig. 23
6.
Disconnect electrical wiring to high limit.
7.
Remove high limit from the rear of low voltage
control box.
Fig. 24
8.
Remove capillary tube from heating element.
Installation
1.
Route capillary bulb through the opening in
heating element mounting plate. Ensure there
are no sharp bends in capillary tubing while
installing.
A.
Insert capillary bulb into the holding tube on
heating element.
2.
Apply pipe thread sealant to threads then install
large capillary tube mounting nut.
F35453 Rev. A (0119)
A.
Ensure capillary bulb is centered in the
holding tube. Tighten the capillary tube
compression nut.
3.
Install heating element with a new gasket.
Torque mounting nuts to 70 in-lbs and tighten
using an alternating pattern.
4.
Secure high limit to low voltage control box then
coil excess capillary tube length near the high
limit.
5.
Check steamer for proper operation and leaks
around heating element gasket and high limit
capillary tube nuts.

CONDENSATE THERMOSTAT

1.
Turn off machine to drain steam generator. Allow
steamer to complete drain cycle.
A.
Turn off water supply.
2.
Remove RIGHT SIDE BASE PANEL as outlined
under Covers and Panels.
3.
Disconnect electrical wiring to condensate
thermostat.
4.
Remove condensate thermostat from the rear of
drain box.
Page 16 of 75
Fig. 25
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.