Power On/Off Button: Press and hold the button for at least 1/2 second, and then release the button to power on or power off the
system.
Pressing and holding the button for at least five seconds will initiate an emergency shut down sequence.
Status Indicators: Colored LEDs show the status of power and capture.
Indicator
Power
Battery State
Host Interface
Capture
Antenna SMA Connector: Antenna attaching point.
Battery Charge : The following table shows the charge state of the installed battery. When the battery is not installed, all LEDs are off
except when the unit is in the process of powering up. In that case they repeatedly light up in sequence.
Frontline Technical Support: Phone +1-434-984-4500 or email tech_support@fte.com
Table 1 - Sodera Front Panel Status Indicators
Color
State
None
Off
Unit is powered off
Green Constant
Unit is switched on
Red
Blinking
Unit is approaching its maximum thermal load and should be shut
down.
Constant
Unit has been automatically disabled due to thermal overload.
Amber Constant
Unit is powering down.
None
Off
No battery present
Green Constant
Battery present and is at normal operating voltage
Slow Flash
Battery charging
Amber Fast Flash
Battery fault
None
Off
No host interface is connected.
Green Constant
Host interface is connected.
Amber Constant
Internal error
None
Off
Unit is not actively capturing data
Green Constant
Unit is capturing data
Red
Constant
Unit has engaged RF overload protection; the RF signal is too strong.
Table 2 - Sodera Battery Charge State LED