Teledyne Frontline Sodera Quick Start Manual page 9

Wideband bluetooth protocol analyzer

Advertisement

In the
and
Wireless Devices
devices can also be selected while the recording is in process.
Note: Data filtered by the device selection is an "OR" function, not an "AND" function. When selecting device1,
device2, device3,... the recorded data filtered into the analyzer is data involving device1 OR device2 OR device3
OR .... However, if in the Options menu, analysis if LE Empty packets is selected an AND function is included.
For example: (device2 AND LE Empty packets) OR (device3 AND LE Empty packets).
The following table lists some common data capture and device selection scenarios.
Scenario
Analyzing traffic between a slave Device Under Test
(DUT) and its master.
Analyzing all traffic on a piconet
Analyzing all traffic involved in Inquiries
The Set in Target is now ready to begin protocol- and event-level analysis.
10. Set in Target: Starting Analysis
The analysis begins by clicking on the
Alternatively, click on the
begin sending captured packets involving the selected device to the Frontline software.
Once analysis has begun, you cannot change the device selection. All device rows in the
Wired Devices
your device selection and restart analysis by clicking on the
To stop the Analysis click on the
Conducting analysis from a capture file is identical to the live capture method.
11. Capturing Set in Target Analyzed Data to Disk
Note:
is not available in Viewer mode.
Record
analyses to be performed on previously recorded and saved captures.
1. Click the
Record
from all wireless devices within range and from all connected wired devices.
2. In the
Wireless Devices
3. Click on
Analyze
button is located on the
4. Files are placed in My Capture Files by default and have a .cfa extension. Choose
window to change the default file location.
Control
5. Watch the Status Bar on the
the oldest data will be overwritten by new data.
Frontline Technical Support: Phone +1-434-984-4500 or email tech_support@fte.com
pane, place a check in the row of each active device
Wired Devices
Table 4 - Common Data Capture and Device Selection Scenarios
Start Analyze
pane are grayed-out. To stop the analysis, click on the
button or click on the
Analyzing
button on the Standard Toolbar. Sodera Sodera LESodera or Sodera LE will begin capturing data
and
pane select the active devices for analysis
Wired Devices
button , or click the
window,
Control
Event Display
window to monitor how full the file is. When the file is full, it begins to wrap, which means
Control
Wireless Devices Pane Selection
Select only the slave DUT for analysis
Select the Master for analysis
In the
Set in Target
Options menu select
in the
menu
Packets
Options
button, or selecting
Analyze
button
In the
Control
Analyze
window
Control
Stop Analyze
is available in Viewer mode, allowing different
Analyze/Analyzing
button
to begin capturing to a file. This
Start Analyze
, and
.
Frame Display
Directories
/
to be analyzed. Active
Analyze Inquiry Process
from the
menu.
Analyze
Capture
window. The Set in Target hardware will
Wireless Devices
button. You can then change
Analyzing
button.
button
.
from the
Options
and
Start Analyze
menu on the