Condition/Problem
No display/partial display/
unit will not turn on
Speed displayed is not
accurate
Speed displayed is always
"0"/stuck in Pause mode
No Speed/RPM reading
Unit operates but
Bluetooth
Heart Rate
®
(HR) not displayed
Unit operates but
Bluetooth
HR displayed
®
incorrectly
Things to Check
Check electrical (wall)
outlet
Check connection at front
of unit
Check data cable integrity
Check data cable
connections/orientation
Check console display for
damage
Console Display
Check Speed Sensor
Magnet position
Data cable
Speed Sensor
Check data cable integrity
Check data cable
connections/orientation
Check Speed Sensor
Magnet position
Check Speed Sensor
Assembly
Bluetooth
Heart Rate
®
Sensing Device (Armband
provided with IC4)
Bluetooth
Heart Rate
®
Sensing Device Batteries
Interference
Replace Heart Rate Sens-
ing Device
Replace Console
Connected to previous
user
Make sure unit is plugged into a functioning wall outlet.
Connection should be secure and undamaged. Replace
adapter or connection at unit if either are damaged.
All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Check for visual sign that console display is cracked or other-
wise damaged. Replace Console if damaged.
If Console only has partial display and all connections are fine,
replace the Console.
If the above steps do not resolve the problem, contact Cus-
tomer Service (if inside US/Canada) or your local distributor (if
outside US/Canada).
Speed Sensor Magnet should be in place on Flywheel.
Make sure the data cable is connected to the Console and the
main frame assembly.
Make sure the RPM Sensor Magnet and the RPM Sensor are
in place.
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Speed Sensor Magnet should be in place on Flywheel.
Speed Sensor Assembly should be aligned with magnet and
connected to data cable. Realign sensor if necessary. Replace
if there is any damage to the sensor or the connecting wire.
Make sure device is directly against skin and contact area is
wet.
If device has replaceable batteries, install new batteries.
Try moving unit away from sources of interference (TV, Micro-
wave, etc).
If interference is eliminated and HR does not function, replace
device.
If HR still does not function, replace Console.
The Console may be still connected to the previous user. Push
Connect Bluetooth
button to disconnect from them/ connect to
®
your Heart Rate Sensing Device.