Figure 21 - Sample Printout (Last Normal Stop); Figure 22 - Sample Printout (Sales Order) - York OPTIVIEW YIA D Operation Manual

Single stage absorption chillers steam/hot water with control center
Table of Contents

Advertisement

Printers
YORK A JOHNSON CONTROLS COMPANY
UNIT MODEL < >
<DATE>, <HOUR>
TOTAL OPERATING HOURS < > [HOURS]
LATEST RUN TIME < > [DAYS, HOURS, MINUTES]
SOFTWARE VERSION < >
- L A S T
N O R M A L
SYSTEM STATUS < >
CONTROL STATUS < >
SYSTEM DETAILS < >, < >, < >
RETURNING CHILLED LIQUID TEMPERATURE............ < >
LEAVING CHILLED LIQUID TEMPERATURE.................. < >
REFRIGERANT TEMPERATURE........................................ < >
ADC LINE TEMPERATURE................................................. < >
STRONG SOLUTION TEMPERATURE............................... < >
STRONG SOLUTION CONCENTRATION.......................... < >
SOLUTION TEMPERATURE LEAVING STS...................... < >
REFRIGERANT FROM CONDENSER TEMEPERATURE.... < >
MIN SOLUTION TEMP TO CRYSTALLIZE........................ < >
RETURNING COOLING LIQUID TEMPERATURE........... < >
LEAVING COOLING LIQUID TEMPERATURE................. < >
ENTERING HOT WATER TEMPERATURE......................... < >
STEAM TEMPERATURE IN................................................. < >
STEAM PRESSURE............................................................... < >
MAX ALLOWED LOADING................................................ < >
CONTROL VALVE POSITION [%]....................................... < >
GENERATOR SHELL PRESSURE........................................ < >
LEAVING CHILLED LIQUID SETPOINT............................ < >
REMOTE TEMP SETPOINT RANGE................................... < >
REMOTE LOAD LIMIT......................................................... < >
AUTOPURGE 7 DAY COUNTER......................................... < >
AUTOPURGE TOTAL COUNTER........................................ < >
PURGE TANK PRESSURE.................................................... < >
PURGE PUMP PRESSURE.................................................... < >
PULLDOWN SETPOINT TIME............................................. < >
PULLDOWN SETPOINT START.......................................... < >
PULLDOWN SETPOINT STOP............................................. < >
CHILLED LIQUID PUMP RUN CONTACTS (ON/OFF)..... < >
CONDENSER LIQUID PUMP RUN CONTACTS (ON/OFF)... < >
CHILLED LIQUID FLOW SWITCH (OPEN/CLOSE)......... < >
CONDENSER LIQUID FLOW SWITCH (OPEN/CLOSE).. < >
REFRIGERANT PUMP (ON/OFF)........................................ < >
SOLUTION PUMP (ON/OFF)............................................... < >
ABSORBER PUMP (ON/OFF) -IF FRANKLIN-.................. < >
GENERATOR PUMP (ON/OFF) -IF FRANKLIN-................ < >
REFRIGERANT LEVEL SWITCH 1F (OPEN/CLOSE)....... < >
REFRIGERANT LEVEL SWITCH 3F (OPEN/CLOSE)....... < >
STABILIZER REFRIGERANT SOLENOID VALVE 2SOL
(OPEN/CLOSE)...................................................................... < >
REFRIGERANT LEVEL SOLENOID VALVE 3SOL
(OPEN/CLOSE)...................................................................... < >
MOTOR COOLANT SOLENOID VALVE 4SOL
(OPEN/CLOSE) -IF FRANKILN-.......................................... < >
FIGURE 21 – SAMPLE PRINTOUT
(LAST NORMAL STOP)
68
SERIAL NUMBER < >
S T O P
R E P O R T -
REV. 1.0 2008
YORK A JOHNSON CONTROLS COMPANY
UNIT MODEL < >
<DATE>, <HOUR>
TOTAL OPERATING HOURS < > [HOURS]
LATEST RUN TIME < > [DAYS, HOURS, MINUTES]
SOFTWARE VERSION < >
- S A L E S
O R D E R
YORK ORDER
VOLTAGE
POWER CONSUMPTION
COOLING CAPACITY..............
DESIGN DATA
EN UNITS
-EVAPORATOR-
EWT.................................
< >
LWT..................................
< >
FLOW...............................
< >
PD.....................................
< >
PASS.................................
< >
DWP..................................
< >
FLUID TYPE....................
FLUID %...........................
< >
-ABSORBER/CONDENSER-
EWT..................................
< >
LWT..................................
< >
FLOW...............................
< >
PD.....................................
< >
PASS.................................
< >
DWP.................................
< >
FLUID TYPE...................
< >
FLUID %.........................
< >
-GENERATOR-
EWT.................................
< >
LWT.................................
< >
FLOW..............................
< >
PD....................................
< >
PASS................................
< >
DWP.................................
< >
FLUID TYPE...................
< >
FLUID %..........................
< >
STEAM CONSUMPTION...... < >
STEAM PRESSURE AT GEN... < >
STEAM PRESSURE AT VALVE..< >
UNIT CONFIGURATION SETTINGS
CONTROL VALVE PART NUMBER.....
CONTROL VALVE DESCRIPTION......
FRANKLIN OR BUFFALO PUMPS.....
UNIT MODEL..........................
ELECTRICAL CODE...............
ENERGY SOURCE..................
FLOW SWITCH TYPE............
LANGUAGE............................
UNITS......................................
FIGURE 22 – SAMPLE PRINTOUT (SALES ORDER)
FORM 155.21-O1 (615)
SERIAL NUMBER < >
R E P O R T -
< >
< >
< >
< > < >
SI UNITS
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
< >
REV 1.0 2008
JOHNSON CONTROLS