5 Installation
5-3-8

Book Mount Procedure

Use the following procedure to mount the Industrial Box PC in the book orientation.
Additional Information
• Refer to 5-4-2 Ground on page 5-26 for grounding details.
• Refer to 3-10-1 Mounting Brackets on page 3-22 for the bracket model.
To mount the Box PC:
1
The Box PC has on one side light grey circles around the threaded mounting holes. The book-
mount bracket has on the inside on one side also the light grey circles around the mounting
holes.
The light grey circles are contact areas that ensure a good electrical conductivity.
Position the Box PC inside the bracket so the light grey circles of the bookmount bracket con-
tact the light grey circles of the Box PC.
2
Mount the bracket A to the Box PC C with the 6 Phillips screws B supplied with the bracket.
First tighten the 3 screws at the side of the contact areas with a torque of 0.5 N·m.
Then tighten the 3 screws at the opposite side, also with a torque of 0.5 N·m.
The bracket and the Box PC can differ depending on the product configuration.
3
Mount the Box PC with the bracket in position.
• Drill the four holes at the location where the Box PC with bracket will be mounted.
Refer to 4-1-9 Bracket Specifications on page 4-17 for details.
• Position the Box PC with bracket in the mounting location.
• Insert screws through the bracket into the mounting surface.
Note that these screws are not in the scope of delivery.
• Tighten all four screws with a torque of 0.5 N·m.
The Box PC is mounted.
5-24
A
B
C
NY-series Industrial Box PC Hardware User's Manual (W553)