Omron SYSMAC LINK C1000H-SLK21-V1 System Manual page 97

Table of Contents

Advertisement

NETWORK READ/WRITE Instructions
(Continued from previous page)
12802
12802
25204
SEND(90)/RECV(98)
12802
25203
Error Flag
12802
25204
12800
Data moved into control data words to specify
@MOV(21)
the 16 words to be transmitted from node 4 in
#0010
operating level 0.
DM 0003
DM 003
@MOV(21)
DM 004
#8000
DM 005
DM 0004
@MOV(21)
#0004
DM 0005
Indirectly addressed beginning destination
@MOV(21)
word. Beginning destination word in destina-
#0500
tion node = DM 5000.
HR 10
HR 10
@MOV(21)
HR 11
#5000
HR 11
@RECV(98)
HR 10
LR 10
DM 0003
DIFU(13)
12801
Turns ON to indicate reception error.
00201
XFER(70)
Transmitted data moved into words beginning
#0016
at DM 0030 for storage.
LR 10
DM 0030
Section 6-2
0 0 1 0
16 words
8 0 0 0
0 0 0 4
Node 4 (a PC)
0 5 0 0
5 0 0 0
83