NETWORK READ/WRITE Instructions
00000
25204
12802
(Enable Flag)
12801
12800
12800
25204
SEND(90)/RECV(98)
Error Flag
12800
25203
00001
25204
12800
12803
12802
12802
25204
SEND(90)/RECV(98)
12802
25203
Error Flag
12802
25204
12800
12800 prevents execution of SEND(90) until
KEEP(11)
12800
RECV(98) (below) is completed. IR 00000 is
S
turned ON to start transmission.
R
@MOV(21)
#000A
Data is placed into control data words to spec-
DM 0000
ify the 10 words to be transmitted to node 3 in
@MOV(21)
operating level 0.
#8000
DM 000
DM 0001
DM 001
@MOV(21)
DM 002
#0003
DM 0002
Transfers the 10 words beginning at IR 000 to
XFER(70)
the 10 words beginning at DM 0010.
#0010
000
DM 0010
@SEND(90)
DM 0010
DM 0020
DM 0000
DIFU(13)
12801
Turns ON to indicate transmission error.
00200
12802 prevents execution of RECV(98) when
KEEP(11)
SEND(90) above has not completed. IR
12802
S
00001 is turned ON to start transmission.
R
@MOV(21)
#0010
DM 0003
Data moved into control data words to specify
@MOV(21)
the 16 words to be transmitted from node 4 in
#8000
operating level 0.
DM 0004
DM 003
@MOV(21)
DM 004
#0004
DM 005
DM 0005
@RECV(98)
HR 10
LR 10
DM 0003
DIFU(13)
12801
00201
Turns ON to indicate reception error.
XFER(70)
Transmitted data moved into words
#0016
beginning at DM 0030 for storage.
LR 10
DM 0030
Section 6-2
0 0 0 A
10 words
8 0 0 0
0 0 0 3
Node 3 (a PC)
0 0 1 0
16 words
8 0 0 0
0 0 0 4
Node 4 (a PC)
81