Omron SYSMAC LINK C1000H-SLK21-V1 System Manual page 148

Table of Contents

Advertisement

Standard Models
Accessories
The required number of each of the following is included with the Auxiliary Power Supply Units. Replacement parts
can be ordered using the following model numbers.
Name
Power Supply Cable (Supplies one Unit.)
Related Items
The following items will be required when connecting two Units to one Power Supply Unit.
Name
Power Supply Cable
Applicable CPU Units
The following table shows which CPU Units are compatible with which SYSMAC LINK Units. The SYSMAC LINK
Units cannot be used with other CPU Units or with a C2000H Duplex System (even one set for Simplex operation.)
A Communications Board equipped with a Link Interface (C200HW-COM01/04-EV1) is required when mounting a
SYSMAC LINK Unit to a C200HX/HG/HE PC.
SYSMAC LINK Unit
C1000H-SLK21-V1
C1000H-SLK11
C200HW-SLK23/24
C200HW-SLK13/14
Connectors and Related Items
The following tables list the optical and coaxial connectors as well as tools used to attach the connectors and test
connections.
Optical-type
Name
Optical Connector
Optical Connector
Assembly Tools
Optical Power Tester
Master Fiber
Note 1. Never use the S3200-COCF2011 Optical Connector with C200HW-SLK13/14 SYSMAC LINK Units.
The connector might become stuck in the Unit if inserted.
134
One is included with the C1000H-APS01.
One is included with the C200H-APS03.
Connects to one Unit. Order one more cable (one is included with the
Power Supply Unit) when connecting two C1000H-SLK11 Units.
Connects to two Units. Order one when connecting two C200HW-
SLK13/14 Units.
Specifications
Coaxial-type
C1000H-CPU01-EV1
C2000H-CPU01-EV1
C2000H CPU01 EV1
Optical-type
C200H-CPU11-E
Coaxial-type
C200H-CPU31-E
C200HS-CPU31-E
C200HS-CPU33-E
C200HX-CPU34-E
C200HX-CPU44-E
C200HX-CPU54-E
C200HX CPU54 E
C200HX-CPU64-E
Optical-type
C200HG-CPU33-E
C200HG-CPU43-E
C200HG-CPU53-E
C200HG-CPU63-E
C200HE-CPU32-E
C200HE-CPU42-E
Connects the optical fiber cable to the C1000H-SLK11. (See note 1.)
Two are required for each node.
Connects the optical fiber cable to the C200HW-SLK13/14. Two are
required for each node. (Can be used with the C1000H-SLK11 too.)
This inline adapter splices optical fiber cable. One is required for each
break in the cable.
For use with the S3200-COCF2071/COCF2571 Optical Connector.
(Optical fiber cable cutters are included)
For use with the S3200-COCF2071/COCF2571 Optical Connector.
(Head Unit model number: S3200-CAT2702)
For use with the S3200-COCF2071/COCF2571 Optical Connector.
Specifications
Specifications
Applicable CPU Unit(s)
Specifications
Appendix A
Model
C1000H-CN111
C200H-CN111
Model
C1000H-CN111
C200H-CN211
Model
S3200-COCF2071
S3200-COCF2571
S3200-COIA2000
CAK-0057
(See note 2.)
S3200-CAT2700
S3200-CAT2001H