10.3 Backup and restore

You can back up or restore preventive maintenance information held in the controller.
To replace the robot body or robot controller only, you need to perform backup/restore of the preventive
maintenance information to migrate the preventive maintenance information.
For backup/restore of the preventive maintenance information, click [Maintenance] - [Backup] of the
preventive maintenance function.
• Replacing the robot controller
When replacing the controller, back up the preventive maintenance information from the previous
controller and restore it in the new controller.
• Exchanging the combination of robot controller and mechanism (between the same models)
When exchanging the combination of controller and mechanism between the same models, before
implementation, back up the preventive maintenance information of the respective controllers and after
implementation restore the information to the replaced controllers.
Backup
1) Backup: Save the preventive maintenance information in the robot controller to a file on a
personal computer.
2) Restore: Transfer the information backed up on the personal computer to the robot controller.
• The preventive maintenance information of the robot body is saved in the robot
Caution
• In order to prevent writing backup data to a different robot, an error (H.7101)
• When the serial number of the connected robot was changed, an error (H.7100) is
• When there is no backup data, all consumption degrees can be reset by
• After replacing the robot controller, if you did not restore the preventive
controller; it is necessary to use the correct combination of the robot body and
robot controller.
To replace the robot body or robot controller only, perform backup/restore of
preventive maintenance information to migrate the preventive maintenance
information.
occurs when the serial number of the robot is different from the backup data value
when restoring.
output upon power on to notify that effect in order to prevent the occurrence of
unmatched preventive maintenance information when exchanging robot.
performing mechanism replacement of maintenance reset. However, in that case,
the consumption degree calculation result cannot be the correct value. (Refer to
"10.2 Maintenance Reset".)
maintenance information or if you restored it a long time after backup was
performed, the consumption degree calculation result cannot be the correct value.
(1) Backup
(2) Restore