Pressure Relief Procedure - Graco EcoQuip EQ200T Operation, Repair, And Parts

Vapor abrasive blast system
Hide thumbs Also See for EcoQuip EQ200T:
Table of Contents

Advertisement

Pressure Relief Procedure

Pressure Relief
Relief Procedure
Pressure
Pressure
Relief
Follow the Pressure Relief Procedure
whenever you see this symbol.
This equipment stays pressurized until pressure
is manually relieved. To help prevent serious
injury from pressurized fluid, such as splashing
fluid, follow the Pressure Relief Procedure when
instructed.
1. Turn the pot pressure regulator (PR) off.
8
Procedure
Procedure
2. Close the abrasive ball valve.
3. Turn the compressor off. Close the compressor
supply air valve.
4. Engage the blast control switch to relieve
pressure in the system.
5. Verify that the supply air pressure gauge reads 0
psi. Then disconnect the air inlet hose from the
system.
6. Turn the selector valve (SL) to FILL.
7. Open the dump valve.
8. Verify that the pot pressure gauge (PG) displays
zero pressure.