Replacing The Datatrak Battery - Graco EcoQuip EQ200T Operation, Repair, And Parts

Vapor abrasive blast system
Hide thumbs Also See for EcoQuip EQ200T:
Table of Contents

Advertisement

Replacing the
the DataTrak
DataTrak Battery
Replacing
Replacing
the
DataTrak
FIRE AND
AND EXPLOSION
EXPLOSION HAZARD
FIRE
FIRE
AND
EXPLOSION
To reduce the risk of fire and explosion, the battery
must be replaced in a non-hazardous location.
Use only an approved replacement battery (see
table). Use of an unapproved battery will void
Graco's warranty.
Replace Battery
Battery
Replace
Replace
Battery
1. Unscrew cable from the back of the reed switch
assembly.
2. Remove the cable from the two cable clips.
334666C
Battery
Battery
HAZARD
HAZARD
3. Remove the DataTrak module from the bracket.
Take the module and attached cable to a
non-hazardous location.
4. Remove the two screws on the back of the
module to access the battery.
5. Disconnect the used battery and replace it with
an approved battery.
Approved Batteries
Approved
Approved
Energizer alkaline #522
Varta alkaline #4922
Ultralife lithium #U9VL
Duracell alkaline #MN1604
Repair
Batteries
Batteries
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecoquip eq400t