Replacing The Datatrak Battery - Graco EcoQuip 300 Operation, Repair, And Parts

Vapor abrasive blast system
Hide thumbs Also See for EcoQuip 300:
Table of Contents

Advertisement

Repair
Replacing the
the DataTrak
DataTrak Battery
Replacing
Replacing
the
DataTrak
FIRE
FIRE
FIRE AND
AND
AND EXPLOSION
EXPLOSION
EXPLOSION HAZARD
HAZARD
HAZARD
To reduce the risk of fire and explosion, the battery
must be replaced in a non-hazardous location.
Use only an approved replacement battery (see
table). Use of an unapproved battery will void
Graco's warranty.
Replace Battery
Battery
Replace
Replace
Battery
1. Unscrew cable from the back of the reed switch
assembly.
2. Remove the cable from the two cable clips.
32
Battery
Battery
3. Remove the DataTrak module from the bracket.
4. Remove the two screws on the back of the
5. Disconnect the used battery and replace it with
Energizer alkaline #522
Varta alkaline #4922
Ultralife lithium #U9VL
Duracell alkaline #MN1604
Get other manuals https://www.bkmanuals.com
Take the module and attached cable to a
non-hazardous location.
module to access the battery.
an approved battery.
Approved Batteries
Approved
Approved
Batteries
Batteries
334667B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecoquip 600Eq300cEq600c

Table of Contents