INTRODUCTION
This manual is applicable only to models listed on the
cover page. Procedures in this manual will apply to all
models unless specified. Pictures and illustrations can
be of any model unless they need to be model specific.
INSTALLATION, OPERATION AND
CLEANING
For detailed installation, operation and cleaning
instructions, refer to the Installation & Operation
Manual sent with each unit. The manual is also
available online at www.vulcanequipment.com.
TOOLS
Standard
•
Standard set of hand tools.
•
VOM with minimum of NFPA-70E CATIII 600V,
UL/CSA/TUV listed. Sensitivity of at least 20,000
ohms per volt and the ability to measure DC
micro amps. Meter leads must also be rated at
CAT III 600V.
•
Clamp on type amp meter with minimum of
NFPA-70E CAT III 600V,UL/CSA/TUV listed.
•
Temperature tester (thermocouple type).
•
ESD (Electrostatic discharge) Protection Kit.
Special
•
Handheld, digital temperature and humidity
sensor Grainger No. 3LYH7 or equivalent.
SPECIFICATIONS
MODELS
VOLTS
120V
VBP and
VPT
240V
F45748 (0219)
V Series Heated Holding Insulated Cabinets - GENERAL
GENERAL
WATTS
AMPS
1,500
12.5
1,500
6.25
Page 4 of 17
DATA PLATE LOCATIONS
DATA PLATE LOCATED ON BACK PANEL
INSIDE DATA PLATE