Component Cooling Fan; Control Board - Vulcan-Hart VBP5 Service Manual

Heated holding insulated cabinets
Table of Contents

Advertisement

V Series Heated Holding Insulated Cabinets - REMOVAL AND REPLACEMENT OF PARTS
Fig. 18
6.
Reverse procedure to install.

COMPONENT COOLING FAN

Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
1.
Remove TOP COVER .
2.
Note and disconnect fan wiring to terminal block
and control board.
3.
Remove fan mounting screws.
Fig. 19
Note air flow direction on fan when replacing fan. (1,
Rotation Fig. 20) (2, Air Flow Fig. 20)
4.
Reverse procedure to install.

CONTROL BOARD

Certain components in this system are subject to
damage by electrostatic discharge (ESD) during field
repairs. An ESD kit is required to prevent damage. The
ESD kit must be used anytime the circuit board is
handled.
1.
Remove TOP COVER .
2.
Note and disconnect board connectors and
wires.
Page 9 of 17
Fig. 20
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.