Timing chart of alarm occurrence

• [G] [WG]
In the torque mode, the forced stop deceleration function cannot be used.
When the servo motor is at a stop due to an alarm or other factors, commands from the controller are not
accepted. When restarting the operation in the cyclic synchronous position mode, confirm the position
command.
• [A]
In the torque mode, the forced stop deceleration function cannot be used.
When using the forced stop deceleration function
When [Pr. PA04.3 Forced stop deceleration function selection] is set to "2" (Forced stop deceleration function
enabled).
■Stopping with forced stop deceleration function
When an alarm is detected, the servo motor stops with the forced stop deceleration, and MBR and ALM are turned off.
Servo motor speed
Base circuit
(Energy supply to
the servo motor)
Servo amplifier
display
MBR
(Electromagnetic
brake interlock)
ALM
(Malfunction)
*1 The model speed command is a speed command generated in the servo amplifier for forced stop deceleration of the servo motor.
3 BASIC FUNCTION
98
3.12 Alarm function
Alarm occurrence
0 r/min
ON
OFF
No alarm
ON
OFF
ON
(No alarm)
OFF
(Alarm)
Commands from the controller are not accepted.
Alarm No.
Model speed command is 0,
and the speed is equal to or
*1
less than zero speed