Message in time
Display
data display
condition
FAN Stopped
off
DR-FAN Stop
off
High TEMP!
off
High TEMP!
off
a) With respect to setting of basic menu item 016
92
8-3 Alarms
Description
a)
The motor of the main unit fan has
stopped.
The motor of a drive fan has stopped.
Temperatures have risen within the unit.
Temperatures have risen within a drive.
Action
Contact your Sony service
representative.
Note
The unit will operate, but continued use
in this state will result in rising
temperatures in the unit or drive, with the
risk of fire or damage to the unit.