Sony PDW-V1 Operation Manual page 89

Sony professional disc recorder pdw-v1 operation manual
Hide thumbs Also See for PDW-V1:
Table of Contents

Advertisement

Message in time
Display
data display
condition
ILL. Index!
off
FORMAT NG!
off
DISC ERROR!
limit
DI read err
off
DRV ADJ err
off
a) With respect to setting of basic menu item 016
During playback
Message in time
Display
data display
condition
525/60 Disc
limit
625/50 Disc
limit
No Support!
off
Disc Error!
off
a) With respect to setting of basic menu item 016
During control panel operations
Message in time
Display
data display
condition
REMOTE!
on
No Disc!
on
REC INHI.!
on
REC INHI.!
limit
REC INHI.!
off
REC INHI.!
off
Description
a)
An index file error was detected.
Automatic format failed.
A disc error occurred during write back.
Data could not be recorded normally.
A disc read error occurred.
Adjustment processing failed when a
disc was inserted.
Description
a)
An attempt was made to play back a disc
recorded with the NTSC system when
this unit is in 625 line mode (PAL
system).
An attempt was made to play back a disc
recorded with the PAL system when this
unit is in 525(U) or 525(J) line mode
(NTSC system).
A disc recorded in an unsupported
recording format was inserted.
Normal playback is not possible because
of a disc defect.
Description
a)
A button was pressed while the remote
control switch was set to "REMOTE."
A button was pressed with no disc
loaded.
An attempt was made to record, display
an E-E display, record an essence mark,
or add a quick scene selection sub clip.
An attempt was made to save the current
clip list on a write-protected disc.
An attempt was made to delete a clip
from a write-protected disc.
An attempt was made to format a write-
protected disc.
Action
Format the disc.
For details, see 3-6-5 "Formatting a Disc"
(page 37).
Use another disc.
This disc cannot be recorded. Exchange
the disc.
Try ejecting the disc and inserting it
again, or insert another disc.
Action
Use a disc recorded with the PAL
system.
Use a disc recorded with the NTSC
system.
Use a disc recorded in the MPEG IMX or
DVCAM format.
Use another disc.
You can check the state of a disc by
checking playback condition marks (see
page 35).
Action
To operate from the control panel, wait
until control by the remote device ends
and then set the remote control switch to
"LOCAL."
Operate after inserting a disc.
Try the operation again after setting the
write-protect tab to the recording enabled
position.
89