Inverter Factory Setting - Siemens SINAMICS G110M Operating Instructions Manual

Distributed converter for simogear geared motors
Hide thumbs Also See for SINAMICS G110M:
Table of Contents

Advertisement

Commissioning
5.2 Prepare basic commissioning
24 Temperature class Th.Cl.
25 Symbols (IEC 60617-2):
26 Rated braking torque T
27 Brake supply voltage U [V]
Frequency 1
28 Rated frequency f [Hz]
29 Rated voltage / range U [V]
30 Circuit, graphical symbols according to DIN EN 60617 Part 6 / IEC 60617-6
31 Rated current I
32 Power factor cos φ
33 Rated power P
34 Efficiency class marking according to IEC 60034-30
35 Rated speed n
Frequency 2
36 Rated frequency f [Hz]
37 Rated voltage / range U [V]
38 Rated current I
39 Power factor cos φ
40 Circuit, graphical symbols according to DIN EN 60617 Part 6 / IEC 60617-6
41 Rated power P N [kW], duty type (if ≠ S1)
42 Efficiency class marking
43 Rated speed n
44 Motor designation, active part
● If you use the STARTER commissioning tool and a SIEMENS motor, you only need to
specify the article number of the motor, otherwise you must note the data from the motor
rating label.
● Pay attention to the connection of the motor (star connection [Y] or delta connection [Δ] ).
Note the appropriate motor data for connecting.
● Motor ambient temperature if it differs from the factory setting = 20° C.
5.2.2

Inverter factory setting

Motor
With its factory settings, the inverter is set up for an induction motor suitable for the power
rating of the Power Module.
98
= brake
[Nm]
Br
[A]
N
[kW], duty type (if ≠ S1)
N
[rpm]
N
[A]
N
[rpm]
N
Operating Instructions, 06/2016, FW V4.7.6, A5E31298649B AG