WARNING
Never install a single wall slip section or smoke pipe in a chase structure. The higher temperature of this single
wall pipe may radiate suffi cient heat to combustible chase materials to cause a fi re.
To avoid danger of fi re, all instructions must be strictly followed, incluidng the provision of air space clearance
between chimney system and enclosure. To protect against the effects of erosion on those parts exposed to
the weather, we recommend that the chase top be painted with a rust-resistant paint.
Maintain a minimum 2" (51mm) air clearance to all parts of the chimney system at all times. Failure to maintain
this 2" (51mm) air clearance will cause a structure fi re.
Detailed instructions for installation of the chase top, storm collar, and termination cap are packaged with these
parts.
Firestop spacers must be used whenever the chimney penetrates a ceiling/fl oor area.
The chimney must be sound and free of cracks. Clean your chimney a minimum of twice a year, and as
required.
A raised hearth, together with the appliance built on a raised platform, is recommended for easier wood loading
and fi re viewing.
5.1

chimney

note:
All venting connections must be in compliance with the chimney manufacturer's installation instructions.
This appliance was tested to CAN/ULC S610 and UL 127 Factory Built Fireplace Standards. This appliance has
met the test criteria for Zero Clearance Installation to Combustible Surfaces and Certifi ed to burn fi rewood only.
Any chimney listed to the following standards; CAN/ULC-S604 and CAN/ULC-S629 for Canada or UL-103 or UL-
103HT for the United States may be installed.
note:
Use only the chimney diameter specifi ed on the rating plate of the
appliance.
Installation of all types of factory-built chimney systems is to be in
accordance with the chimney manufacturers installation instructions.
An appropriate chimney manufacturers anchor base plate and anchor
base plate gasket is required in order to initiate their system. Use
the high temperature gasket, supplied, to seal between the anchor
plate and the appliance top. Air cooled chimney systems are not
recommended in colder climates.
For complete installation instructions, refer to instructions provided with
the manufactured chimney system.
A chimney venting the appliance shall not vent any other appliance. The minimum overall chimney height from
the top of the appliance is 15ft (4.6m). The maximum overall chimney height from the top of the appliance is 34ft
(10.4m).
Factory-built chimney systems for use in dwellings constructed for three or more families must be enclosed
above the room in which the appliance is located. This enclosure must have a fi re resistance rating equal to or
greater than that of the fl oor or roof assembly through which they pass.
The chimney should not be built with an offset angle in excess of 45° in Canada and 30° in USA.
Ensure that minimum clearances are maintained.
Portions of the chimney that extend through accessible spaces must always be encased to avoid personal
contact with the chimney and thereby avoid damage to the chimney.
The chimney must be supported at a maximum of 20ft (6.1m) intervals. Every 20 ft (6.1m) of chimney can weigh
up to approximately 200lbs (90.7kg).

5.0 installation

ANCHOR PLATE
ANCHOR PLATE GASKET
APPLIANCE TOP
ANCHOR PLATE FOR A FACTORY
BUILT CHIMNEY