2) If Originator is occupied:
SMDR START/DIAL
PULSE (ROTARY):
SMDR START/DTMF: This grace period timer starts SMDR recording for
SYS HOLD RECALL: This timer determines the time calls can be left on hold
TRANSFER RECALL: This timer determines the time transferred calls ring
UCDS AUDIO ALM:
UCDS VISUAL ALAM: This timer determines how long the longest waiting call
VMS UCD MSG TM:
PERI UCD REPORT: This is periodic time for printing out UCD data.
e–hold ße–hold recall timeà recall to originator ßrecall à recall toßrecallà
disconnect
transfer trsf recall time
with off hook ring
This grace period timer starts SMDR recording for rotary
dialling. This timer also controls the LCD duration timer
on the keysets. The duration time displayed and the
SMDR time duration will be the same.
touchtone dialling. This timer also controls the LCD
duration timer on the keysets. The duration time
displayed and the SMDR time duration will be the same.
before recalling the holding station. This is a system–wide
timer. Setting timer to 000 means no recalling will take
place.
before recalling. This is a system–wide timer. See Recall
Wait Time.
This timer determines how long the longest waiting call
can be held before the system gives an audio alarm to the
UCD supervisor.
can be held before the system gives a visual alarm to the
UCD supervisor.
This timer controls the duration of time that VMS gives
UCD busy indication to user.
MMC 501 (Page 7 of 7)
Programming
February, 1999
wait time operator disc.time