Daikin RMXS-L Series Service Manual page 7

Multi-split 8-zone heat pump systems
Hide thumbs Also See for RMXS-L Series:
Table of Contents

Advertisement

SiUS181305E
8. Thermistor Resistance / Temperature Characteristics............................224
9. Pressure Sensor .....................................................................................226
10.Method of Replacing Inverter's Power Transistors Modules...................227
Part 9 Appendix ............................................................................ 229
1. Piping Diagrams......................................................................................230
2. Wiring Diagrams......................................................................................234
3. Removal Procedure (Booklet No.) ..........................................................239
Legends
Ta
Tb
Tc
Tdi
Te
Tfin
Tl
Tp
Tr
Ts
Ts1
Ts2
Tsh
Tt
HTdi Value of discharge pipe temperature (Tdi) compensated with outdoor temperature
SC
SH
Pc
Pe
vi
7.33 Check for Outdoor Unit............................................................................. 220
1.1 Outdoor Unit ............................................................................................. 230
1.2 Branch Provider (BP) Unit ........................................................................ 231
1.3 Indoor Unit................................................................................................ 232
2.1 Outdoor Unit ............................................................................................. 234
2.2 Branch Provider (BP) Unit ........................................................................ 235
2.3 Indoor Unit................................................................................................ 236
Outdoor temperature
Outdoor heat exchanger temperature
High pressure equivalent saturation temperature
Discharge pipe temperature
Low pressure equivalent saturation temperature
Radiation fin temperature
Liquid pipe temperature
Value of compressor port temperature calculated by Tc and Te, and suction superheated
degree
Room thermistor temperature
Set temperature
Suction pipe temperature 1
Suction pipe temperature 2
Subcooling heat exchanger gas pipe temperature
Target temperature
Difference between the heat exchanger temperature and liquid pipe temperature of each
indoor unit
Difference between the heat exchanger temperature and gas pipe temperature of each
indoor unit
High pressure sensor detection value
Low pressure sensor detection value