Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Drive MOTOr
Drive Motor Connector
See page 4-32 for the procedure for accessing
the drive motor.
1.
Unplug washer of disconnect power.
2.
Disconnect the 5-wire connector from the
drive motor.
3.
Set the ohmmeter to the R X 1 scale.
4.
Touch the ohmmeter test leads to
the following motor pins. For each
measurement, the meter should indicate
approximately 6 Ω.
Pins 1 and 2
Pins 2 and 3
Pins 1 and 3
Electrical Shock Hazard
See page 4-26 for the procedure for accessing
a ground switch.
Pin 1
1.
Unplug washer or disconnect power.
2.
Disconnect the wire connectors from either
of the ground switch terminals.
3.
Set the ohmmeter to the R X 1 scale.
4.
Touch the ohmmeter test leads to the
2 ground switch terminals. The meter
should indicate an open circuit (infinite Ω)
with the actuator button pushed in, and a
Closed circuit (0 Ω) with the actuator button
released.
5-7
GrOunD SWiTCH
Actuator Button
Com
N.C.