When reinstalling the tub to pump hose,
align the air hose fitting with the opening at
the right side of the tub opening flange.
n
There is also an alignment arrow on the
pump that should be aligned with the notch
on the hose.
Arrow
Notch

reMOve GrOunD SWiTCH

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug washer or disconnect power.
2.
Turn off the water supply to the washer.
3.
Remove the lower service panel
(See page 4-21)
or
Remove the rear panel (See page 4-28).
Front Ground Switch
4-26
Rear Ground Switch