Remove Service Switch (Model Mhn30Pd); Main Top Support - Maytag 30 Series Service Manual

30 commercial front loading washers
Table of Contents

Advertisement

reMOve ServiCe SWiTCH
(MODeL MHn30PD)
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug washer or disconnect power.
2.
Remove the service access door from the
metercase.
3.
Remove one 5/16" hex head screw to
release the bracket that holds the service
switch.
4.
Remove the switch, bracket and wire
harness.
1.
Unplug washer or disconnect power.
2.
Turn off the water supply to the washer.
3.
Lift the washer top (See page 4-3).
nOTe: There are two parts that make up
the top support. The angle support is glued
to the underside of the top. The cross brace
is attached to the side panels with a 1/4"
5/16" Hex
hex screw at each end. It has 3 foam pads
Head Screw
glued onto it. When the top is closed, the
angle support presses into the glued on
foam pads of the cross brace to help reduce
vibration of the top and / or metercase.
4-46

Main TOP SuPPOrT

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Angle Support
Foam Pads
Cross Brace