Commissioning
4.7 Basic commissioning with IOP
14. Set the Minimum Speed at which the attached motor
15. Set the Ramp Up time in seconds.
16. Set the Ramp Down time in seconds.
17. A summary of all the settings is displayed.
18. The final screen gives two options:
78
should run.
This is the time the Inverter/motor system will take from
being given the run command, to reaching the selected
motor speed.
This is the time the Inverter/motor system will take from
being given the OFF1 command, for the motor to reach a
standstill.
If the settings are correct, select Continue.
• Save settings
• Cancel Wizard
If save is selected, a factory reset will be performed then
the settings are saved to the Inverter memory. The loca-
tion of saved data is assigned using the "Parameter sav-
ing mode" function in "Parameter settings" in "Menu".