Description
2.2 SINAMICS G110M converter
Table 2- 3
SINAMICS G110M Options
Option
24 V Power supply
Internal braking resistor (FSA)
Internal braking resistor (FSB)
Glanded connector kit
HanQ connector kit
Compatible motors for the SINAMICS G110M system
The following tables detail the motors that are compatible with the SINAMICS G110M
system.
Due to the unique nature of the SINAMICS G110M system, there are a number of
restrictions regarding the type of options and devices used with the motors. These are listed
below:
● No encoders can be used.
● The brake lever cannot be used in the "12 O'Clock" position; this is not possible because
of the position of the terminal housing of the Inverter.
● The use of only 180 Vdc brakes are permissible.
● 230/400 Vac brake voltage is not allowed.
● Standby heating of the motor is not allowed.
● An external motor fan cannot be fitted if the terminal housing is in the "12 O'Clock"
position.
18
Description
Internal 24 V DC power supply for the CU240M
10% duty cycle with 5% peak braking power, peak power
75 W, instantaneous power 1.9 kW, average power 7.5 W,
resistance 350 Ohms.
10% duty cycle with 5% peak braking power, peak power
200 W, instantaneous power 3.8 kW, average power 20
W, resistance 175 Ohms.
Comprises the following connectors:
M20 screw gland - used for 24 V power supply daisy
•
chain
M25 plastic gland - used for the 3-phase mains daisy
•
chain
M12 plastic gland - used for the EM-brake cable entry.
•
Comprises the following connectors:
Connector cap 7/8th internal thread - used for the 24 V
•
power blanking cap
HanQ blanking cap - used for the mains input blank-
•
ingcap
M12 plastic gland - used for the EM-brake cable entry.
•
Order number
6SL3555-0PV00-0AA0
6SL3501-0BE18-8AA0
6SL3501-0BE22-0AA0
6SL3566-2VA00-0GA0
6SL3566-2LA00-0GA0
SINAMICS G110M Getting Started
Getting Started, 09/2014, FW V4.7, A5E31298643B AC