Rules for the use of the motors:
● Rated output current of the converter ≥ rated input current of the motor.
● For the SINAMICS G110M use only the following types of motors:
– SIMOTICS GP 1LA, frame size 71
– SIMOTICS GP 1LE1 frame sizes 80, 90 100 and 112.
● The motors must be configured with the terminal box on the B-side (BS) of the motor
(NDE = Non Drive End) as shown in the figure below. For this configuration, select the
following options during the motor selection:
– For SIMOTICS GP 1LA motors, option M64
– For SIMOTICS GP 1LE1 motors, option H08 (in preparation for 1LE1 motors for frame
Figure 2-2
Table 2- 4
2-pole, 400 VAC, 50 Hz motors
SINAMICS G110M characteristics
HO power
Rated output
(kW)
current (A)
0.37
1.30
0.75
2.20
1.1
3.10
SINAMICS G110M Getting Started
Getting Started, 09/2014, FW V4.7, A5E31298643B AC
sizes 80 and 90).
Correct motor types
Motor characteristics
Frame size
Order num-
ber
FSA
1LA9070-
2KA
FSA
1LA7070-
2AA
FSA
1LA7070-
2AA
FSA
1LA9070-
2KA
FSA
1LE1001-
0DA2
FSA
1LA7070-
2AA
FSA
1LA9070-
2KA
FSA
1LE1001-
0DA2
FSA
1LE1001-
0DA3
2.2 SINAMICS G110M converter
Power (kW)
Frame size
0.37
71M
0.37
71M
0.37
71M
0.37
71M
0.75
80M
0.37
71M
0.37
71M
0.75
80M
1.10
80M
Description
Rated current
Efficiency
(A)
0.95
IE2
0.99
IE1
0.99
IE1
0.95
IE2
1.67
IE2
0.99
IE1
0.95
IE2
1.67
IE2
2.40
IE2
19