Controller System; After Replacing The Main Controller Pcb - Canon D1300 Series Service Manual

Table of Contents

Advertisement

5
Adjustment > Actions after Replacement Parts > Controller System > After Replacing the Main Controller PCB

Controller System

■ After Replacing the Main Controller PCB

Actions before Replacement
Perform backup of user data (such as Settings/Registration data) and service mode data to
set/register them again after replacing the PCB. Write down the data which cannot be backed
up.
1) Export user data using remote UI.
2) Insert the USB memory into the host machine, and execute COPIER > FUNCTION >
SYSTEM > EXPORT to write the setting values of the service mode (excluding those
related to the Reader/DADF) to the USB memory.
3) Write down the serial number of the host machine and each factory adjustment value
written on the service label. (Enter them after replacement.)
Actions after Replacement
1) Error code "E248-0001" lights up when turning ON the power.
2) Execute COPIER > FUNCTION > CLEAR > R-CON.
3) Enter all items written on the service label.
4) Set the location group and paper size group.
• COPIER > OPTION > BODY > LOCALE (setting the location group)
[Setting value]
1: Japan, 2: North America, 3: Korea, 4: China, 5: Taiwan, 6: Europe, 7: Asia, 8:
Oceania
• COPIER > OPTION > BODY > SIZE-LC (setting the paper size group)
[Setting value]
1: AB configuration, 2: Inch configuration, 3: A configuration, 4: AB/Inch configuration
5) Clearing the Settings/Registration data
Execute COPIER > FUNCTION > CLEAR > ALL.
When executing this item, the following data is cleared according to the values of LOCALE
and SIZE-LC set in step 4.
• Settings/Registration data (the initial value according to the location is set.)
• Service mode data (the initial value according to the location is set.)
• Job ID
• Each log data
• Date data
Note that the following data is not cleared.
• Service counter
• Adjustment value of Reader/DADF
5
Adjustment > Actions after Replacement Parts > Controller System > After Replacing the Main Controller PCB
6) Execute COPIER > FUNCTION > VIFFNC > STOR-DCN (the setting value of DC Controller
is backed up.)
7) Turn OFF and then ON the power.
8) Operate according to the instruction on the screen since the initial installation mode is
activated. (Setting the date/time, executing the auto gradation adjustment)
9) Enter the serial number (8-digit alphanumeric) in Settings/Registration > System Settings >
Device Information > Location.
10) After selecting COPIER > OPTION > SERIAL > SN-MAIN, press OK key to write the
serial number entered in step 4 in the Main Controller PCB. After writing, the serial number
entered in "Location" in step 9 is deleted.
11) Turn OFF and then ON the main power.
12) Execute COPIER > FUNCTION > MISC-P > SPEC to output the spec report to check the
serial number (Body.No.).
13) Enter the data backed up earlier in Settings/Registration > System Settings > Device
Information > Location.
14) Import the service mode data backed up before replacement.
Insert the USB memory storage device to the slot of the machine, and execute COPIER >
FUNCTION > SYSTEM > IMPORT.
15) Import user data using remote UI.
16) Uninstall the drivers on the user's PC.
• Printer driver
• Fax driverr
• Scanner driver
• Network Scan Utility (in case of network connection)
* For the procedure, refer to "When Deleting the Installed Software" in the Startup Guide.
17) Install the drivers again which were uninstalled in step 16.
* For the procedure, refer to the following items in the Startup Guide.
In case of network connection: "Installing the Network Connection"
In case of USB connection: "Installing the USB Connection"
5-4
5-4