Korg Minilogue XD Owner's Manual page 41

Polyphonic analogue synthesizer
Hide thumbs Also See for Minilogue XD:
Table of Contents

Advertisement

Button 5 (GLOBAL 3)
These parameters relate to the SYNC IN and OUT jacks settings.
Sync In Unit
This sets how much the arpeggiator will advance with each pulse received via the SYNC IN jack.
16th Note: The sequencer will advance one sixteenth note for each pulse.
8th Note: The sequencer will advance one eighth note for each pulse.
Sync Out Unit
This sets when to send each pulse via the SYNC OUT jack, according to how far the arpeggiator has advanced.
16th Note: A pulse will be outputted for every sixteenth note.
8th Note: A pulse will be outputted for every eighth note.
Sync In Polarity
In order to achieve synchronization with other units, the polarity of the SYNC IN jack may need to
be changed.
Rise: The minilogue xd will create a sync pulse as it rises to its crest (the highest point) of the waveform.
Fall: The minilogue xd will create a sync pulse as it falls to its trough (the lowest point) of the waveform.
Sync Out Polarity
In order for other units to correctly sync with the minilogue xd, the polarity of the SYNC OUT jack
may need to be changed.
Rise: The minilogue xd will create a sync pulse as it rises to its crest (the highest point) of the waveform.
Fall: The minilogue xd will create a sync pulse as it falls to its trough (the lowest point) of the waveform.
Button 6 (GLOBAL 4)
These parameters relate to the minilogue xd's MIDI capabilities.
MIDI Route
MIDI signals can be sent and received via the MIDI connector and USB port, or by the USB port alone.
USB+MIDI: MIDI messages are received via the USB B port and the MIDI IN connector; messages
are transmitted from the USB B port and the MIDI OUT connector.
USB: MIDI messages will be transmitted and received only via the USB B port. When using the
USB port as a MIDI interface, it is advantageous to use this setting.
MIDI Ch
Specifies the global MIDI channel of the minilogue xd.
This MIDI channel is used to transmit and receive note messages, as well as control change mes-
sages like pitch bend and data dump messages.
Clock Source
Many features of the minilogue xd can be synchronized to the tempo or BPM. This parameter
specifies whether the clock source is internal, or an external MIDI clock source.
Auto (USB), Auto (MIDI): When there is no input, the internal clock will be used. When input is
detected, the internal clock will be synchronized to external MIDI clocks from the USB B and MIDI
IN connectors respectively.
Internal: Only the internal clock will be used.
When a cable is plugged into the SYNC IN jack, the internal clock is synchronized to the
SYNC IN jack clock, regardless of the MIDI clock settings.
En Rx Transport
Sets whether transport-related messages received as part of MIDI real-time messages such as start,
stop and continue will be received.
[16th Note, 8th Note]
[16th Note, 8th Note]
[Rise, Fall]
[Rise, Fall]
[USB+MIDI, USB]
[1...16]
[Auto (USB), Auto (MIDI), Internal]
[Off, On]