Escalator with Automatic Operation Function
(Weekly Timer, OFF Delay Timer)
Application
The ZEN can be simply used to conserve energy for an escalator with an automatic
operation function. The escalator can be set to operate continuously from 7:00 to 10:00
and 17:00 to 22:00 weekdays and then operate at other times and on weekends only
when people step on the escalator.
System Configuration
R S T
200 VAC
DC power
supply
+
Contactor
or inverter
Q0
IM
Escalator drive motor
124
Group 1 lit
SQ0
Group 2 lit
SQ1
Group 3 lit
SQ2
Group 4 lit
SQ3
Group 1 lit
SQ0
RQ1
Group 2 not lit
Group 3 lit
SQ2
RQ3
Group 4 not lit
I0
Sensor to detect approaching person
I1
Operation switch
Stop switch
I2
+ –
NC
ZEN-
10C1DR-DA
I2 (Pattern 2)
08
09
10
11
I3 (All lights OFF)
12
13
14
15
Use two weekly timers for the 7:00 to 10:00
and 17:00 to 22:00 weekday operation.
For the rest of the time, use an OFF delay
timer to operate the escalator for 3 minutes
when pedestrians are detected.
Appendix D
Group 1 lit
SQ0
Group 2 lit
SQ1
Group 3 not lit
RQ2
Group 4 not lit
RQ3
RQ0
Group 1 not lit
Group 2 not lit
RQ1
Group 3 not lit
RQ2
Group 4 not lit
RQ3