Drive the flushing unit with manually operation button.
3.
Once it is confirmed that there is no leakage after the
connection of supply tube, put the manually operation to
its original place. Mount the slurry mold onto the valve
box and apply slurry into the crevice around the valve
box and smooth the surface.
Notice:
a. Please confirm the completion of the outlet
connection or no leakage during the
application of water supply.
b. Please avoid breaking the manual lever line
during this procedure.
c. Avoid the plug-ins from wetting,or this will
result in false operations of the sensor.
用手动按钮组件驱动冲洗器,试通水,确认各管道连接处无
3.
渗漏后,将手动拉线组件放回原位。将灰浆模装于阀盒上,
阀盒周围空隙用灰浆抹平。
试水过程中确认出水口连接完成或封堵无误。
注意:
a.
b.
防止接插件受潮,否则将引起误动作。
4.
When the slurry turns solid,remove the short screws,pull
out slurry mold,mount the bracket assembly,and secure
with long screws.
灰浆固化后,取下短螺钉,揭去灰浆模,并用长螺钉固定安
4.
装架。
7
35
Valve Box
暗盒
+30
105
0
Slurry Mold
灰浆模
Tiles
瓷砖
Slurry Mold
灰浆模
Manually Operation button
手动按钮
Screws M4 10
M4 10
螺钉
Screws
M4 50
螺钉M4 50