BEFORE YOU BEGIN
·
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
·
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
·
These instructions contain important care, cleaning, and
warranty information-please leave instructions for the
consumer.
ORDERING INFORMATION
REVE WH Toilet (HT100 TL IWT) ........................K-24766T-S
Includes REVE Wall-hung Toilet Bowl..................K-5051T
Includes HYDRO-TOWER 100
Touchless In-Wall Tank.................K-6281T-RES
Includes REVE Quiet-close Toilet Seat........K-17183T-CP
REVE WH Toilet (HT200 PNE IWT).....................K-24767T-S
Includes REVE Wall-hung Toilet Bowl..................K-5051T
Includes HYDRO-TOWER 200 PNE
In-Wall Tank ................................K-20007T-RES
Includes REVE Quiet-close Toilet Seat........K-17183T-CP
REVE WH Toilet (HT300 PNE IWT).....................K-24768T-S
Includes REVE Wall-hung Toilet Bowl..................K-5051T
Includes HYDRO-TOWER 300 PNE
In-Wall Tank ................................K-20010T-RES
Includes REVE Quiet-close Toilet Seat........K-17183T-CP
REVE WH Toilet (HT300 MEC IWT) ....................K-24769T-S
Includes REVE Wall-hung Toilet Bowl..................K-5051T
Includes HYDRO-TOWER 300
In-Wall Tank W/ Frame .................K-4179T-RES
Includes REVE Quiet-close Toilet Seat........K-17183T-CP
REVE WH Toilet (HT100 MEC IWT) ....................K-24770T-S
Includes REVE Wall-hung Toilet Bowl..................K-5051T
Includes HYDRO-TOWER 100
In-Wall Tank W/ Frame .................K-6284T-RES
Includes REVE Quiet-close Toilet Seat........K-17183T-CP
REVE WH Toilet (HT100 PNE IWT).....................K-24698T-S
Includes REVE Wall-hung Toilet Bowl..................K-5051T
Includes HYDRO-TOWER 100 PNE
In-Wall Tank W/ Frame ...............K-22524T-RES
Includes REVE Quiet-close Toilet Seat........K-17183T-CP
No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137
8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA
NO.1 KOHLER STREET, ECONOMIC DEVELOPMENT ZONE OF FAKU COUNTY, SHENYANG LIAONING PROVINCE, PRC
1268139-T01-D
K-23132T-CPS/K-23132T-BNS/K-23133T-CPS/K-23133T-BNS/K-25445T-NS
·
·
·
·
-1-
INSTALLATION INSTRUCTIONS
K-24766T-S/K-24767T-S/K-24768T-S/K-24769T-S
K-24770T-S/K-24698T-S/K-24697T-S/K-24699T-GS
(
100
.....................................K-5051T
100
.................................K-17183T-CP
(
200
.....................................K-5051T
200
...............................K-20007T-RES
.................................K-17183T-CP
(
300
.....................................K-5051T
300
...............................K-20010T-RES
.................................K-17183T-CP
(
300
.....................................K-5051T
300
........................................K-4179T-RES
.................................K-17183T-CP
(
100
.....................................K-5051T
100
........................................K-6284T-RES
.................................K-17183T-CP
(
100
.....................................K-5051T
100
...............................K-22524T-RES
.................................K-17183T-CP
2
528137
8
256410
1
110400
©
Copyright Kohler China Investment Co., Ltd. 2020
©
REVE
WALL-HUNG TOILET
).........K-24766T-S
.........................K-6281T-RES
)................K-24767T-S
)................K-24768T-S
)................K-24769T-S
)................K-24770T-S
)................K-24698T-S
:
POST CODE:
256410
POST CODE:
110400
2020
-

Advertisement

Table of Contents
loading

Summary of Contents for Kohler REVE K-24766T-S

  • Page 1 In-Wall Tank W/ Frame ....K-22524T-RES .........K-17183T-CP Includes REVE Quiet-close Toilet Seat..K-17183T-CP No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137 528137 8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA...
  • Page 2: Tools And Materials Required

    REVE WH Toilet (HT100 TL IWT) ......K-24697T-S )..K-24697T-S Includes REVE Wall-hung Toilet Bowl....K-5051T ........K-5051T Includes HYDRO-TOWER 100 Touchless In-Wall Tank W/ Bevel FP ...K-21298T-RES .......K-21298T-RES Includes REVE Quiet-close Toilet Seat..K-17183T-CP .........K-17183T-CP REVE WH Toilet (BEAM M FV) ......K-24699T-GS ) ....K-24699T-GS Includes Bowl ..........K-24919T-GS ............K-24919T-GS Includes BEAM Manual Toilet/Squat...
  • Page 3 ROUGHING-IN Reference Value Unit: mm 365 200 Fig.#1 Kohler reserves the right to change marked dimensions without prior notice. INSTALLATION 1. Install Flushing Mechanism 1-1. Install The Tank 1-1. 1) Turn the water supply off before installing the new toilet.
  • Page 4 2. Set The Spacing Of The Bowl After you install the tank, be careful to set the spacing of set aside the length for carrier studs and tighten nut. The bowl on wall according to the dimensions as shown. See Fig. #3. Unit: mm NOTE: Please reserve 10mm space for the nut strictly according to the...
  • Page 5 4. Install The New Toilet 1) Install the accessory kit into the installing hole. 2) Place the new toilet on the wall through the carrier. 3) Use wrench to tighten accessories and level the toilet. Then finish fixation. 4) Insert the cap into installing hole. See Fig. #6. Fig.#6 5.
  • Page 6: Consumer Responsibilities

    CAUTION: Don t use any cement while installing the toilet. Heat expansion of the toilet may damage the feet of the toilet. Kohler will not be responsible for any damage because of using cement. WARNING: Risk of product damage. Do not throw into the toilet what is easy to block it, such as newspaper, paper pilch, sanitary towel.
  • Page 7: Before You Begin

    Kohler will not be responsible for any damage related to above mentioned cleanser or solvent. Mild detergent can be used. Do not apply spares that are not provided by Kohler, and please note that glass adhesive tape shall not be applied to the installation of Kohler spares.
  • Page 8: Function Explanation

    ,2.6/4.0L ......................K-25439T-PNE-NA ,3.0/4.5L ......................K-25440T-PNE-NA ,3.0/6.0L ......................K-25441T-PNE-NA ,2.6/4.0L( ) ..................K-25442T-PNE-NA ,3.0/4.5L( ) ..................K-25443T-PNE-NA ,3.0/6.0L( ) ..................K-25444T-PNE-NA ,3.5/5.0 ( ) .....................K-25440T-RE-NA ,3.5/5.0 ( ) ..................K-25440T-VAW-NA ,3.5/5.0 ( ) ....................K-25440T-VL-NA ,3.5/5.0 ( )...................K-25443T-RE-NA ,3.5/5.0 ( )................K-25443T-EA-NA ,3.0/4.5 ( ) ..................K-25440T-PM-NA ,3.0/4.5 ( ) ..................K-25443T-PM-NA ,3.0/4.5 ( ) .....................K-25440T-RU-NA ,3.0/4.5 (...
  • Page 9: Specifications

    Advantages Of In-wall Tank Made of macromolecular materials that prevents corrison and leaking. Advanced water tank fitting, which makes possible the adjustment of the water discharge and double flush. Will not affect the structure of the wall and provides excellent sound insulation. Easy installation and time efficient.
  • Page 10 RECOMMENDES TOOLS AND MATERIALS RECOMMENDES TOOLS AND MATERIALS Open end/adjustable wrenches Allen wrench Knife File Hacksaw Masonry Level Screw driver Insulation tape Tape measure Seal tape Bushing Lubricant ROUGHING-IN Reference Value UNIT: mm K-25439T-PNE/K-25440T-PNE/K-25440T-RE/K-25440T-VAW K-25440T-VL/K-25440T-DNW/K-25440T-PM/K-25440T-RU/K-25440T-ML/K-25441T-PNE Installed with K-20341T-PNE K-20341T-PNE Method three: Method one: Method two: Remote installation...
  • Page 11 Elbow Drain outlet 90mm, welding A B C 90mm Water Tank Bracket Discharge Elbow Drain outlet 110mm 110mm Water Tank Bracket Discharge Elbow Drain outlet 110mm, welding 110mm Kohler reserves the right to change marked dimensions without prior notice. 1402749-T01-A...
  • Page 12: Installation

    INSTALLATION Way of Installation There are two ways to install this product: in-wall tank with frame & in-wall tank without frame In-wall Tank With Frame In-wall Tank Without Frame Cover,Top Installation For In-wall Tank With Frame Cover,Front A. Installation of In-wall Tank 1.
  • Page 13 Washer 3. Drill four holes with diameter of 12mm and depth of 80mm Expanding Bolt Cap with churn drilling as shown, and fill in the holes with expanding bolt cap and tighten the screw. Screw 12mm 80mm Screw Washer Expanding Bolt Cap 4.
  • Page 14 2. Tighten the long screw into the holes of the tank bracket Inlet Hole and cover the drainage hole with the big cap, cover the Tank Bracket inlet hole with the small cap. Small Cap Long Screw Drainage Hole Big Cap 3.
  • Page 15 A. Method one: Install mask when pressing from top. Mask Remove top plate, then install the rectangular shield Cover,Top on the top of the tank, and tighten the screw to fix the Screw mask to the tank. B. Methods two and three: During remote installation, fix Cover,Top the cover onto the tank and pull the air hose to the Cover,Front...
  • Page 16 C. Method four: Cut apart the cable of the air hose. Pull Method four: it out from the front of the tank and meanwhile Press from front reserve the access panel. Fix the four plates with screws and then fix the support board. Pinch plate Finished wall Air hose...
  • Page 17 2. Tighten the long screw into the holes of the tank bracket and cover the drainage hole with the big cap, cover the Small Cap Water Inlet inlet hole with the small cap. Long Screw Drainage Hole Big Cap Water Tank Bracket Access Panel 3.
  • Page 18 3. Install the big and small leak-proof gaskets on inlet pipe and outlet pipe ,then install it to corresponding pipes on the toilet tank. Small Leak-proof Gasket Inlet Pipe Drainage Pipe Big Leak-proof Gasket 4. 48mm-58mm of the long screw shall be reserved outside the wall as shown in the illustration.
  • Page 19: Faceplate Installation

    E. Faceplate Installation According to different faceplates, there are different faceplate installations as below: Supporting Board 1. K-20341T-PNE/K-75890T-PNE/K-24149T/K-24151T Locknut installation 1. K-20341T-PNE/K-75890T-PNE/K-24149T/K-24151T When tighten four locknuts on supporting board, adjust to "OPEN" mark as shown. OPEN 2) Tighten four screws to "LOCK" mark after installing supporting board as shown.
  • Page 20 4) It is ready to use when connected to water supply after installation. Note: Reserve access panel at front or top of the tank in Full Flush remote installation. Button Half Flush Button 2. K-23055T-PNE installationn 2. K-23055T-PNE Suggested faceplate fixed frame installation direction Air Hose Connect air hose to faceplate from water tank Faceplate...
  • Page 21 Cover,Top Installation For In-wall Tank Without Frame Cover,Front A. Installation of In-wall Tank 1. Remove in-wall tank from packing box. Remove front cover board or top cover board inside water tank first as shown. Then remove paper board, support block and plug above bracket assembly.
  • Page 22 4. Connect tap water braided tube on the top of water tank for water supply as shown. Connecting Pipe Note: 1. Ensure water tank internal valve is OFF. 2. Suggestion: connect a temporary rubber or plastic Water Pipe hose on valve, flush water supply pipeline. Ensure water is clean, no residual sand stone or fouling inside pipeline.
  • Page 23 B. Methods two and three: During remote installation, fix Cover,Top the cover onto the tank and pull the air hose to the Cover,Front panel. Reserve access panel at front or top to ensure removal and installation of cover. Air hose Finished wall Method two: During remote plate installation,...
  • Page 24 2) K-23055T-PNE access panel installation and installation hole size 2) K-23055T-PNE There is only remote installation with K-23055T-PNE, During remote installation, fix the cover onto the tank and pull the air hose to the panel. Reserve access panel At least 80mm gap reserved at front to ensure removal and installation of cover.
  • Page 25 REMOVE AND MAINTENANCE OF THE OUTLET VALVE REMOVE AND MAINTENANCE OF THE OUTLET VALVE 1. Remove the air hoses of the big flush and small flush. Then remove the faceplate. Faceplate Faceplate Connect to air hose 2. Pay special attention when dismantle supporting board 4 lock nuts, all bolts shall align with "OPEN"...
  • Page 26 5. Unscrew the nut of the metal weaved hose and push the connector of the inlet valve as shown to remove the inlet valve. Conntector,Quick release Metal weaved hose nut 6. Push aside the snap of the toilet detergent box to take the box out.
  • Page 27 9. Pull discharge valve along the arrow direction as shown to remove discharge valve. Outlet Valve 10. Remove discharge valve as shown and then take valve out for cleaning. Outlet Valve Outlet Valve Press for Top A Wash Filtration Net Close corner valve first, then loosen and take out the tighten nut, and wash the waste on filtration net with clean water.
  • Page 28: Troubleshooting Procedures

    Inlet Valve B. Adjust Inlet Valve Hoist and reduce the water level in the tank by adjusting Control Pole the control pole. Turn the control pole counterclockwise to lower down the floating box and reduce the water level of the tank .turn the control pole clockwise to hoist the floating box and increase the water level in the tank.

Table of Contents