Kohler ESCALE K-25091T-S Installation Instructions Manual
Kohler ESCALE K-25091T-S Installation Instructions Manual

Kohler ESCALE K-25091T-S Installation Instructions Manual

Floor standing toilet

Advertisement

Quick Links

BEFORE YOU BEGIN
BEFORE YOU BEGIN
·
Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
·
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
·
These instructions contain important care, cleaning, and
warranty information -
consumer
.
·
Fixture dimensions are nominal and conform to tolerances
established by ASME Standards (A112.19.2-2013).
·
This product complies with GB 25502-2017. Water
Efficiency Grade 1.
ORDERING INFORMATION
ESCALE WF Toilet(HT200 PNE IWT) ..................K-25089T-S
Includes Bowl ........................................................K-4097T
Includes HYDRO-TOWER 200 PNE
In-Wall Tank W/O Frame .............K-78074T-ESS
Includes ESCALE Quick-Release QC Seat ....K-4417T-2P
ESCALE WF Toilet(HT300 PNE IWT) ..................K-25090T-S
Includes Bowl ........................................................K-4097T
Includes HYDRO-TOWER 300 PNE
In-Wall Tank W/O Frame .............K-78077T-ESS
Includes ESCALE Quick-Release QC Seat ....K-4417T-2P
ESCALE WF Toilet(HT300 MEC IWT)..................K-25091T-S
Includes Bowl ........................................................K-4097T
Includes HYDRO-TOWER 300
In-Wall Tank W/O Frame .............K-10611T-ESS
Includes ESCALE Quick-Release QC Seat ....K-4417T-2P
No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137
8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA POST CODE: 256410
1269084-T01-C
please leave instructions for the
K-25089T-S/K-25090T-S/K-25091T-S
·
·
·
·
2013)
·
GB 25502-2017
(
..................................................................K-4097T
200
(
..................................................................K-4097T
300
(
..................................................................K-4097T
300
2
528137
8
256410
©
Copyright Kohler China Investment Co., Ltd. 2018
-1-
©
ESCALE
INSTALLATION INSTRUCTIONS
FLOOR STANDING TOILET
ASME
(A112.19.2-
1
200
).........K-25089T-S
....................K-78074T-ESS
................................K-4417T-2P
300
).........K-25090T-S
....................K-78077T-ESS
................................K-4417T-2P
300
).........K-25091T-S
...........................K-10611T-ESS
................................K-4417T-2P
-
2018

Advertisement

Table of Contents
loading

Summary of Contents for Kohler ESCALE K-25091T-S

  • Page 1 ......K-10611T-ESS Includes ESCALE Quick-Release QC Seat ..K-4417T-2P ........K-4417T-2P No.2 KOHLER ROAD, SANSHUI CENTRAL INDUSTRIAL PARK, LEPING TOWN, SANSHUI DIST., FOSHAN, GUANGDONG, PRC POST CODE 528137 528137 8# MENGSHAN RD, ECONOMIC DEVELOPMENT ZONE OF HUANTAI, ZIBO, SHANDONG, CHINA POST CODE: 256410 256410 ©...
  • Page 2 SAFETY: WARNINGS Kohler products are precision-engineered and should give continued superior and safe performance, provided: 1. They are installed, commissioned, operated and maintained in accordance with the recommendations given in this Manual. 2. Periodic attention is given, as necessary, to maintain the product in good functional order.
  • Page 3: Specification

    Finished Wall P-trap Finished Wall With 12504A-NA S-trap(For Separate Purchase) 110~130 12504A Fig.#1 Kohler reserves the right to change marked dimensions without prior notice. SPECIFICATION Plumbing Connections Recommended inlet connections are 3/8 BSP. " 3/8" BSP INSTALLATION INSTALL THE TANK 1.
  • Page 4 Install the Toilet 1. Install the waste outlet and water inlet as shown. UNIT mm S.trap P.trap Fig.#3 2. Put the bowl in position, and using a pencil, mark the position of the bowl on the floor, as shown. Mark the positions for the tank attachment bolts on the wall.
  • Page 5 4. Adjust the distance between centerline of PVC waste pipe and the floor (wall) to match it consistent with marked roughing-in. UNIT mm Fig.#6 Installation of S trap: Fix S trap onto wall with expansion screw and insert into the reserved drainage pipe(Fig.7). Push the bowl to insert the drainage hole into the S trap and also insert the water pipe into the outlet of the in-wall tank.
  • Page 6: User Maintenance

    CAUTION: Don t use any cement while installing the toilet. Heat expansion of the toilet may damage the feet of the toilet. Kohler will not be responsible for any damage because of using cement. WARNING: Risk of product damage. Do not throw into the toilet what is easy to block it, such as newspaper, paper pilch, sanitary towel.
  • Page 7: Before You Begin

    Kohler will not be responsible for any damage related to above mentioned cleanser or solvent. Mild detergent can be used. Do not apply spares that are not provided by Kohler, and please note that glass adhesive tape shall not be applied to the installation of Kohler spares.
  • Page 8: Function Explanation

    ,2.6/4.0L ........................K-20006T-PNE ,2.6/4.0L ........................K-20006K-PNE ,3.0/4.5L ........................K-20007T-PNE ,3.5/5.0L( ) ....................K-20007T-VLS ,3.5/5.0L( )....................K-20007T-DNSW ,3.5/5.0L( ) ....................K-20007T-DNW ,3.5/5.0L( ) ....................K-20007T-VABW ,3.5/5.0L( )....................K-20007T-RES ,3 /4.5L ........................K-20007K-PNE ,3.0/6.0L ........................K-20008T-PNE ,3.0/6.0L ........................K-20008K-PNE ,2.6/4.0L( ) ...................K-78073T-PNE ,2.6/4.0L( ) ...................K-78073K-PNE ,3.0/4.5L( ) ...................K-78074T-PNE 3.5/5.0 ) ..................K-78074T-RES 3.5/5.0 ) ................K-78074T-ESS 3.0/4.5 ) ..................K-78074T-VLS 3.0/4.5...
  • Page 9: Specifications

    Advantages Of In-wall Tank Made of macromolecular materials that prevents corrison and leaking. Advanced water tank fitting, which makes possible the adjustment of the water discharge and double flush. Will not affect the structure of the wall and provides excellent sound insulation. Easy installation and time efficient.
  • Page 10 RECOMMENDES TOOLS AND MATERIALS RECOMMENDES TOOLS AND MATERIALS Open end/adjustable wrenches Allen wrench Knife File Hacksaw Masonry Level Screw driver Insulation tape Tape measure Seal tape Bushing Lubricant ROUGHING-IN Reference Value UNIT: mm K-20006T-PNE/K-20006K-PNE/K-20007T-PNE/K-20007T-VLS/K-20007T-DNSW K-20007T-DNW/K-20007T-VABW/K-20007T-RES/K-20007K-PNE/K-20008T-PNE/K-20008K-PNE Installed with K-20341T-PNE K-20341T-PNE Method three: Method one: Method two: Remote installation...
  • Page 11 Drain outlet 110mm 110mm Tank Bracket Water Tank Drainage Pipe Bracket Discharge Fixing Frame Elbow Knob Bottom of the Drainage Pipe Drainage Hole Drain outlet 110mm, welding 110mm Kohler reserves the right to change marked dimensions without prior notice. 1288818-T01-B...
  • Page 12 INSTALLATION Way of Installation There are two ways to install this product: in-wall tank with frame & in-wall tank without frame In-wall Tank With Frame In-wall Tank Without Frame Cover,Top Installation For In-wall Tank With Frame Cover,Front A. Installation of In-wall Tank 1.
  • Page 13 3. Drill four holes with diameter of 10mm and depth of 80mm with churn drilling as shown, and fill in the holes with bulge Bulge Screw screw and tighten the screw. 10mm 80mm Gasket Bulge Screw Cap/Bolt 4. Tighten the hexagonal long screw with medium Allen key Hexagonal Screw as shown in illustration A.
  • Page 14 B. Floor Discharge Installation Method Water Tank Bracket Discharge 1. There are three methods (A, B and C) for drainage pipe Elbow installation. Loosen the knob open on the fixing frame, " " put the drainage pipe into the fixing frame, then adjust and tighten the knob lock .
  • Page 15 Method one: Method two: 4. According to different faceplates,there are different Press from top Remote plate installation installations of access panel as below. Suggested faceplate Pinch installation area plate R1000mm 1) K-20341T-PNE/K-75890T-PNE Access Panel Installation Methods: There are four ways to install access panel: Method one: Press from top Method two: Remote plate installation: fix four plates with screws...
  • Page 16 B. Methods two and three: During remote installation, fix Cover,Top the cover onto the tank and pull the air hose to the Cover,Front panel. Reserve access panel at front or top to ensure removal and installation of cover. Fix Mask Onto Wall Air hose Finished wall...
  • Page 17 2) K-23055T-PNE access panel installation and installation hole size 2) K-23055T-PNE There is only remote installation with K-23055T-PNE, During remote installation, fix the cover onto the tank and pull the air hose to the panel. Reserve access panel at front to ensure removal and installation of cover. At least 80mm gap reserved 80mm Pinch Plate...
  • Page 18 Access Panel 3. When finishing the brickwork of the wall, take out the big Mask and small caps, and eliminate unwanted mask with a sharp knife, if there is mask. Note: Reserve access panel at front or top of the tank. Access Panel Small Cap Big Cap...
  • Page 19: Faceplate Installation

    4. 48mm-58mm of the long screw shall be reserved outside the wall as shown in the illustration. if the long screw outside the wall is not long enough or much longer than that needed, it should be adjusted with screwdriver or by hand.
  • Page 20 2) Tighten four screws to "LOCK" mark after installing supporting board as shown. LOCK 3) Install the big flush air hose and small flush air hose to the cover. Put the lock on the cover directly on the reversed lock on supporting board, then push the cover and lock it.
  • Page 21 Air Hose Connect air hose to faceplate from water tank Faceplate Insert faceplate into faceplate fixed frame with half flush Half Flush Button upward. Installation is completed. Full Flush Button 4) It is ready to use when connected to water supply after installation.
  • Page 22 2. Make sure of h according to dimensions of bowl and then Bulge Screw locate the installation hole of fixing bracket. Mark on the wall for appropriate position for fixing bracket, and drill four Fixing Bracket holes with diameter of 10mm and depth of 80mm with churn drilling as shown in illustration, and fill in the holes with bulge screw and tighten the screw to set the fixing bracket.
  • Page 23 Method one: Method two: 6. According to different faceplates,there are different Press from top Remote plate installation installations of access panel as below. Suggested faceplate installation area R1000mm 1) K-20341T-PNE/K-75890T-PNE Access Panel Installation Methods: Pinch plate There are four ways to install access panel: Method one: Press from top Method two: Remote plate installation: fix four plates Air hose...
  • Page 24 Cover,Top B. Methods two and three: During remote installation, fix the cover onto the tank and pull the air hose to the Cover,Front panel. Reserve access panel at front or top to ensure removal and installation of cover. Air hose Finished wall Method two: During remote plate installation,...
  • Page 25 2) K-23055T-PNE access panel installation and installation hole size 2) K-23055T-PNE There is only remote installation with K-23055T-PNE, During remote installation, fix the cover onto the tank and pull the air hose to the panel. Reserve access panel At least 80mm gap reserved at front to ensure removal and installation of cover.
  • Page 26 REMOVE AND MAINTENANCE OF THE OUTLET VALVE REMOVE AND MAINTENANCE OF THE OUTLET VALVE 1. Remove the air hoses of the big flush and small flush. Then remove the faceplate. Faceplate Faceplate Connect to air hose 2. Pay special attention when dismantle supporting board 4 lock nuts, all bolts shall align with "OPEN"...
  • Page 27 5. Unscrew the nut of the metal weaved hose and push the connector of the inlet valve as shown to remove the inlet valve. Conntector,Quick release Metal weaved hose nut 6. Push aside the snap of the toilet detergent box to take the box out.
  • Page 28 9. Pull discharge valve along the arrow direction as shown to remove discharge valve. Outlet Valve 10. Remove discharge valve as shown and then take valve out for cleaning. Outlet Valve Outlet Valve Press for Top A Wash Filtration Net Close corner valve first, then loosen and take out the tighten nut, and wash the waste on filtration net with clean water.
  • Page 29: Troubleshooting Procedures

    Inlet Valve B. Adjust Inlet Valve Control Pole Hoist and reduce the water level in the tank by adjusting the control pole. Turn the control pole counterclockwise to lower down the floating box and reduce the water level of the tank .turn the control pole clockwise to hoist the floating box and increase the water level in the tank.
  • Page 30 1288818-T01-B -24-...

This manual is also suitable for:

Escale k-25090t-sEscale k-25089t-s

Table of Contents