Configuration

Software Programs for Configuration
Overview of Configuration Commands
Motor Settings
24
Gemini GV Hardware Installation Guide
www.comoso.com
You can configure the Gemini drive's settings for optimum system performance.
For most of these settings, configuration is optional—if you do nothing, the drive
will use default values the very first time it powers up. If you change any settings,
the new settings are saved automatically. Most changed settings are effective
immediately, but some require that you issue a reset (software RESET command,
reset input, or cycle power) before the drive acts upon them.
This chapter will give an overview of all software commands that configure drive
settings. For more in depth descriptions about the software commands, see the
separate Gemini Programmer's Reference.
At the end of this chapter, we have provided tuning procedures you can use to
configure the Gemini drive's tuning settings.
Two software programs are located on the Motion Planner CD-ROM. Motion
Planner runs on a personal computer (PC). Pocket Motion Planner runs on a palm
PC or Handheld Personal Computer (HPC) that uses Windows CE 2.0 or higher,
or on a PC. These programs are also available on the Compumotor web site at
http://www.compumotor.com.
Information about installing and using each of these software tools can be found in
the Gemini Programmer's Reference.
Motion Planner and Pocket Motion Planner's configuration procedures present
commands in groups organized by function. The overview below is organized
similarly to the software's Full Configuration procedure. (Express Setup, which
was discussed in Chapter 2 Installation, gives you fewer configuration options.)
If you select a Compumotor motor from the list of motors the software presents to
you, the software will send settings to the drive for the motor you selected. No
further motor setting configuration is necessary on your part.
If you use a non-Compumotor motor, or choose to manually configure a
Compumotor motor, use the following commands to configure motor settings.
Also see Appendix B – Using Non-Compumotor Motors for additional instructions.
Command
Description
ERES
feedback resolution (encoder or resolver)
DMTIC
continuous current
DMTICD
continuous current derating
DMTKE
motor constant
DMTRES
line-to-line resistance
DMTJ
rotor inertia
DPOLE
number of pole pairs
DMTW
rated speed
DMTIP
peak current