Protective Circuits - Parker Gemini GV Series Installation Manual

Digital servo drives
Table of Contents

Advertisement

Protective Circuits

Short Circuit Protection
Inrush Current Protection
Drive Overtemperature Protection
Motor Overtemperature Protection
74
Gemini GV Hardware Installation Guide
www.comoso.com
The Gemini drive has an internal circuit that protects it from short circuits between
one motor terminal to another (phase to phase), or from any motor terminal to
earth. A short circuit fault is a latched fault.
Short circuit fault caused by:
Results of Fault:
The Gemini drive has internal circuitry that protects it from high inrush current
when power is initially applied to the drive. The circuitry works automatically.
Inrush Current
Drive
Limiter (ohms):
GV-L3n
5Ω
GV-U3n
10Ω
GV-U6n
10Ω
GV-U12n
10Ω
GV-H20n
10Ω
GV-H40n
20Ω
The shorting relay removes the inrush current limiter after drive startup. This
allows maximum bus voltage during high acceleration/peak torque/maximum
speed applications.
Inrush current is temperature dependent:
Ambient Temperature:
25°C (77°F)
50°C (122°F)
The Gemini drive's overtemperature circuit monitors the drive's internal tempera-
ture sensors. If the sensors exceed the threshold temperature, the drive issues an
overtemperature fault.
Threshold Temperature:
Results of Fault:
The Gemini drive has two motor overtemperature circuits:
Hardware Switch:
a thermal switch is embedded in Compumotor motor windings
2
t Thermal Model:
the drive's internal operating software predicts motor winding
I
temperature, based on motor parameters.
Phase to phase short circuit
Phase to earth short circuit
Power to motor is turned OFF
LEDs: Left = illuminated RED; Right = off
Fault output is activated
Latched fault
Current limiter bypassed
with shorting relay:
yes
yes
yes
yes
yes
yes
Inrush Current Limit:
less than 35 amps
less than 70 amps
All drives except GV-H20n:
80°C (176°F)
GV-H20n:
90°C (194°F)
Power to motor is turned OFF
LEDs: Left = illuminated RED; Right = off
Fault output is activated
Latched fault

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gemini gv-h20Gemini gv-u3Gemini gv-h40

Table of Contents