DRIP PIPING / FACADES / SPLASHGUARDS / BUMPERS
3-4
Identify the corresponding positions on the
facade panel, then fasten the hinges to the
facade panel with provided screws.
Facade Panel
Fasten Hinges to Facade
Raise the elevator bolts at the bottom of the
facade. Attach reinforcement straps to the
Facade Panel with provided screws.
Reinforcement
Vertical Facade
Fasten Reinforcement Strap
Air Baffle
Brace
A
Install Air Baffle
P/N 0527427_M
Hinge
18-in.
Facade
Elevator Bolt
DETAIL A
Strap
Facade
Strap
Air Baffle
(20 in.)
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
Position the facade centered on case length
and recessed from the fascia as shown in the
side view. One hinge will be between the
condensing unit and the electrical box. If
necessary, the electrical box can be relocated.
Line up trim channel edge with edge of facade panel
Attach facade channel to top of
canopy fascia using #8 x 1/2 sheet
metal screws provided. Place front
of trim channel at edge of flat sur-
face on canopy fascia top.
Air Baffle
Brace
Fasten the hinge.
Fasten the reinforcement straps after hinges
are attached using provided screws.
Reinforcement
Vertical Facade
Strap
Facade
Strap
A
Air Baffle
(20 in.)

Advertisement

Table of Contents
loading

Table of Contents