REFRIGERATION / ELECTRICAL / CONTROLLER

FIELD INSTALLATION OF CONDENSING UNIT

In some circumstances store doors may not be
tall enough to pass the electrical components
through the door. In this situation, the electri-
cal components may be removed temporarily
to pass under lower frame store doors.
Condenser mounting brackets are provided
on top of the case with pilot holes with specif-
ic attachment points for the condensing unit
base. The mounting brackets are located on
the top right side of the case.
After mounting the condensing unit, the
electrical box must be re-attached to the top.
The condensate pan, if provided, is packed
inside the case and must also be installed on
top of the case and wired into the terminal
strip provided. Exact component location is
not critical; however, the components should
be mounted in the general locations shown to
ensure that electrical connections reach, and
the condensate pan has adequate air flow
from the condenser.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Opening condensing unit electrical box
exposes personnel to electrical hazard
and should only be performed by a
qualified service technician!
noTe:
e
ach uniT lengTh
differenT locaTions for condensing uniT
and elecTrical componenTs
s
ee drawings of The componenT locaTion
.
nexT Two pages