15. Commissioning Cont.
8
Figure 15.9
• Electrically power the boiler, the following
will appear on the LCD display.
Figure 15.10
• To enter Chimney cleaning mode, enter
programming by pressing the reset
button 6 in Figure 15.9 for 10 seconds
until parameter P01 appears on the LCD
display; the following will appear on the
LCD display (the sequence P01 alternates
-- -- --).
Figure 15.11
• Press the reset button 6 Figure 15.9
to scroll the various parameters until
reaching the valid parameter P09 for
the Chimney cleaning mode setting: the
following will appear on the LCD display
(the sequence P09 alternates with 00).
47 RIVA ADVANCE COMBI MANUAL
7
6
Figure 15.12
• Turn the hot water temperature adjustment
knob 8 in Figure 15.14 to the minimum, the
following will appear on the LCD display
(the sequence P09 alternates with 01.
Figure 15.13
MIN
Figure 15.14
• The activation of Chimney cleaning also
is indicated on the LCD display by the
symbols shown in Figure 15.15 turning on
alternately.
MAX
9

Hide quick links: