MAINTENANCE
Check the Engine Coolant
Level
Maintaining the engine coolant at the proper level is
essential to engine service life. Improper coolant
level will affect the engine's cooling capability and
damage engine components. Daily checks will
allow the inspector to identify changes in coolant
level that might indicate cooling system problems.
1 Check the fluid level in the coolant recovery
tank. Add fluid as needed.
Result: The fluid level should be in the
range.
NORMAL
Bodily injury hazard. Fluids in the
radiator are under pressure and
extremely hot. Use caution when
removing cap and adding fluids.
Scheduled Maintenance
The scheduled maintenance items must be
completed by a person trained and qualified to
perform maintenance on this machine according to
the procedures found in the service manual for this
machine.
Inspections and maintenance described below
require the qualified entity to record and retain
records of all inspections and maintenance items
for four years.
Machines that have been out of service for more
than three months must receive the quarterly
inspection before placing the machine back into
service.
16
The Schedule
There are five types of maintenance inspections
that must be performed according to a schedule—
daily, quarterly, six months, annual, two year. To
account for repeated procedures, the Scheduled
Maintenance Procedures Section and the
Maintenance Inspection Report have been divided
into five subsections—A, B, C, D and E. Use the
following chart to determine which group(s) of
procedures are required to perform a scheduled
inspection.
Inspection
Daily or every 8 hours
Quarterly or every 250 hours
Six months or every 500 hours
Annual or every 1000 hours
Two year or every 2000 hours
Maintenance Inspection Report
The maintenance inspection report contains
checklists for each type of scheduled inspection.
Make copies of the Maintenance Inspection Report
to use for each inspection. Store completed forms
for three years.
Genie GS-2668 RT & Genie GS-3268 RT
First Edition · Tenth Printing
Table or Checklist
A + B + C
A + B + C + D
A + B + C + D + E
Part No. 48735
A
A + B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs-3268 rt

Table of Contents