Considerations For Performance/Specifications; Supported Software Packages - Mitsubishi Electric Melsec Q Series User Manual

Programmable contoller mes interface module
Hide thumbs Also See for Melsec Q Series:
Table of Contents

Advertisement

2
SYSTEM CONFIGURATION

2.6.5 Considerations for performance/specifications

(1) Startup time
The time from when a CPU module is started to when the processing of MES
interface function is ready for execution in an MES interface module varies depending
on the system configuration and settings.
The startup time can be lengthened depending on any of the following factors:
When using 'Value monitoring startup' or 'Handshake operation' for a trigger condition,
check that 'Information linkage status (X5)' is in execution (ON), and create a program
so that the trigger condition is satisfied.
(2) Processing time
For the reference value of the processing time, refer to the following.

2.7 Supported Software Packages

(1)
The following table shows the software packages supported by an MES interface
module.
Software package
MX MESInterface
GX Developer
GX Works2
GX Works3
• Operating environment (network and the CompactFlash card)
• Settings of the MES interface module
• Number of DB bufferings
• Model name of the MES interface module (QJ71MES96N, QJ71MES96)
Section 7.10.2 (6) Value monitoring startup
Section 7.10.2 (8) Handshake operation
Appendix 4 Processing Time
Table 2.12 Software packages supported by an MES interface module
QJ71MES96N
All versions
Version 8.500W or later
Version 1.570U or later
Version 1.040S or later
2.6.5 Considerations for performance/specifications
QJ71MES96
All versions
Version 8.37P or later
All versions
All versions
2.7 Supported Software Packages
1
2
3
4
5
6
7
8
2
- 26

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj71mes96Qj71mes96nSw1dnc-mesif-e

Table of Contents